44
GB
IE
LIGHTING AND ADJUSTING THE MAIN BURNER MOD. CPT…
On the front panel, above each knob, the burner it corresponds to is indicated by the index
To light, turn the knob to the left from position “0” to the symbol (see figure);
keep it pushed down and press the button with the symbol until the gas lights
Keep the knob pressed a few second and then let it go, this lights the pilot.
If the flame goes out you have to repeat the procedure.
By turning the knob round to the position the burner is at maximum
By turning the knob round to the position the burner is at minimum.
To switch off, move the knob back into position " 0".
OPERATION MOD. CP…
1) When powering the green on-off device, the red light flashes briefly for about ½ second.
2) In the absence of water in the tank the red light keeps flashing.
3a) Turn on the tap to load the tank to the desired level, which must be higher than the minimum level probe and do not
exceed the maximum level, which is marked on the tank by the symbol (
―
)
3b) In models with automatic load, the water starts loading and you can select the desired level by pressing the button
with symbol (level button)
4) Turn the gas knob to the position and hold it down.
At the same time, press the button to turn on the gas to light the pilot.
5) Turn the gas knob to the position: The burner will remain off until the water reaches the
minimum level probe.
6) To set the burner to the minimum, turn the gas knob to the position.
TURNING OFF THE APPLIANCE
Push and turn the knob into position “0”. This command blocks the gas supply to both the main burner and the pilot
burner. To relight the appliance, it is necessary to turn the knob
again into position and press the button.
EMPTYING THE TUB MOD. CPT...
The user should be equipped with a suitable container for the
drained water. Insert the outlet pipe as shown on the
drawing and place the container in position. Push the safety device
(A) upwards and move lever (B) to the symbol.
Important: pay attention to the clearance between the appliance
and the edges of the stands
.
NB:
it is recommended to carry out this operation using water
which is not too hot.
EMPTYING THE TUB MOD. CP…
To carry out this operation, it is necessary to open the outlet tap (lever in vertical position) which can only be reached
through the cabinet door situated below the appliance.
NB:
it is recommended to carry out this operation using water which is not too hot.
SAFETY THERMOSTAT MOD.CPT…
The appliance is provided with a safety thermostat which interrupts the gas flow if the temperature goes above the
maximum set value. When the safety device intervenes, both the main burner and pilot burner go out.