background image

LOUROE  ELECTRONICS    6 9 5 5   V

  AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

Website:   www.louroe.com            Email: sales@louroe.com

ALJEAN

   

   

(818)

E

L

OUROE

LECTRONIC S

MANUFACTURED

IN THE

Page 8 of 8

AOP-SP-E  8/09

Summary of Contents for AOP-SP-E

Page 1: ...OPERATING INSTRUCTIONS The gain of the microphone and speaker are factory adjusted If it is necessary to change the gain of either or both the audio output of the microphone and speaker of the unit it has to be done in small increments For adjusting the gain of the microphone rotate clockwise to increase or counterclockwise to decrease the potentiometer marked MIC slowly until the desired level is...

Page 2: ...ked A B C SP Bring in other end and connect as follows 1 Red wire to terminal A 2 Black wire to terminal B 3 Bare wire to terminal C 4 White wire to terminal SP This completes the wiring between the AOP SP E and AOP XD For operation instructions and functions regarding Model AOP XD Transceiver Interface unit refer to the AOP XD instructions that accompany the unit Color Code of recommended wiring ...

Page 3: ...D AOP XD AUDIO TRANSCEIVER INTERFACE INPUT INPUT AUDIO AUDIO OUTPUT OUTPUT A U D I O P A T H A U D I O P A T H RCA Plug Color Code of recommended wiring is RED 12Vdc power to microphone BLACK Audio Output BARE Ground microphone WHITE Speaker 24 Vdc 1A POWER SUPPLY INCLUDED Microphone Connection Terminal Block Identifier A 12Vdc power B Audio Output C Ground SP Speaker Connection WIRING REQUIREMENT...

Page 4: ...ONNECTION White Wire Black Wire Black Wire White Wire Red Wire Bare Wire M O N O S T E R E O Audio Out Audio In Red Wire Black Wire White Wire Bare Wire WIRING REQUIREMENTS 3 Conductor consisting of 2 Conductor shielded 20 gauge with 22 gauge drain 1 Conductor unshielded 20 gauge All in the same jacket 12Vdc 500mA power required AD 1 power supply included Connect to this 2 pin terminal block ELECT...

Page 5: ...t to this 2 pin terminal block IP NETWORK CAMERA audio input audio output ELECTRET CONDENSER MICROPHONE AOP XD is not used for this application 12 Vdc power is required to connect the AOP SP E directly to an IP camera or DVR such as AD 1 power supply Positive 12Vdc connects to terminal marked Negative 12 Vdc or ground onnects to terminal marked GND wire with white stripes c An adaptor mono to ster...

Page 6: ...of 8 SPECIFICATIONS Microphone Microphone output Type line level 0 dB 1kΩ Electret Condenser Supply voltage 12 Vdc 500mA SPECIFICATIONS Speaker Speaker Power output Speaker Impedance Speaker magnet Speaker size Weight net 2W 8Ω 3 oz ceramic 4 10cm 3 Lbs 1 4 Kg Microphone element sensitivity Frequency response Output Impedance 45dB 40 Hz to 15 kHz 1 dB 600Ω unbalanced SPECIFICATIONS Mechanical Dime...

Page 7: ...ipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation misuse accident or in violation of installation instructions provided by LOUROE ELE...

Page 8: ...UROE ELECTRONICS 6 9 5 5 V AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 Website www louroe com Email sales louroe com ALJEAN 818 E LOUROE LECTRONICS MANUFACTURED IN THE Page 8 of 8 AOP SP E 8 09 ...

Reviews: