         Doc: I271PLGB0217_DMG700                                      06/07/2010 

s. 16 / 23

 

P07.n.03 

Format danych 

8 bit – n  

8 bit, bez parz.

8 bit, nieparz. 

8bit, parz. 

7 bit, nieparz. 

7 bit, parz. 

P07.n.03

Data format

 8 

bit 

– n 

8 bit, no parity

8 bit, odd 

8bit, even 

7 bit, odd  

7 bit, even 

P07.n.04 

Bity Stop 

1-2

P07.n.04

Stop bits

 

1-2

P07.n.05 

Protoko

ł

y Modbus 

RTU 

Modbus RTU

Modbus ASCII 

Modbus TCP 

P07.n.05

Protocol

 Modbus 

RTU 

Modbus RTU

Modbus ASCII 

Modbus TCP 

P07.n.06 

Adres IP 

000.000.000

.000 

000.000.000.000 –

255.255.255.255

P07.n.06

IP Address

 

000.000.000.000

000.000.000.000 –

255.255.255.255

P07.n.07 

Podmaska sieci 

000.000.000

.000

 

000.000.000.000 –

255.255.255.255

P07.n.07

Subnet mask

 

000.000.000.000

000.000.000.000 –

255.255.255.255

P07.n.08 

Port IP 

1001 

0-9999

P07.n.08

IP port

 

1001 

0-9999

P07.n.09 

Funkcja bramki 

OFF 

OFF/ON

P07.n.09

Gateway function

 

OFF 

OFF/ON

P07.n.10 

Klient / serwer 

Serwer 

Klient / Serwer

P07.n.10

Client / server

 

Server 

Client / Server

P07.n.11 

Zdalny adres IP 

000.000.000

.000

 

000.000.000.000 –

255.255.255.255

P07.n.11

Remote IP address

 

000.000.000.000

000.000.000.000 –

255.255.255.255

P07.n.12 

Zdalny port IP 

1001 

0-9999

P07.n.12

Remote IP port

 

1001 

0-9999

P07.n.13 

Adres IP bramki 

000.000.000

.000

 

000.000.000.000 –

255.255.255.255

P07.n.13

IP gateway address

 

000.000.000.000

000.000.000.000 –

255.255.255.255

Uwaga: To menu jest podzielone na 2 cz

ęś

ci, ka

ż

da dla jednego z kana

ł

ów 

komunikacyjnych COM1 i COM2 
P07.n.01

 – Adres seryjny dla protoko

ł

ów komunikacyjnych. 

P07.n.02

 – Pr

ę

dko

ść

 przesy

ł

u danych. 

P07.n.03

 – Format danych. Mo

ż

e by

ć

 ustawiony na 7 bitów dla protoko

ł

ów ASCII. 

P07.n.04

 – Numer bitu STOP. 

P07.n.05

 – Wybór protoko

ł

ów komunikacyjnych. 

P07.n.06, 08, 13

 – Koordynaty TCP-IP dla aplikacji z modu

ł

em Ethernet. Nie u

ż

ywane 

przy innego typu modu

ł

ach komunikacji. 

P07.n.09

 – Funkcja nie jest obs

ł

ugiwana. 

P07.n.10

 – W

łą

czanie po

łą

czenia TCP-IP. 

Serwer

 = urz

ą

dzenie oczekuje na 

po

łą

czenie z urz

ą

dzenia zdalnego typu Klient. 

Klient

 = urz

ą

dzenia ustanawia 

po

łą

czenie do zdalnego serwera. 

P07.n.11, 12

 – Koordynaty pod

łą

czenia do zdalnego serwera, gdy w parametrze 

P07.n.10 wybrano Klient. 

Note: this menu is divided into 2 sections, for comm channels COM1..2
 
P07.n.01

 – Serial address (node number) for the communication protocol. 

P07.n.02

 – Serial communication speed. 

P07.n.03

 – Data format. Can be set to 7 bits only for ASCII protocol. 

P07.n.04

 – Number of stop bits. 

P07.n.05

 – Communication protocol selection. 

P07.n.06, 08, 13

 – TCP-IP coordinates for application with Ethernet interface. Not 

used for other types of interface modules. 

P07.n.09

 – Not supported function. 

P07.n.10

 – Enebling TCP-IP connection. 

Server

 = Awaits connection from a 

remote client. 

Client

 = Establishes a connection to the remote server. 

P07.n.11, 12

 – Coordinates for the connection to the remote server when 

P07.n.10 is set to Client. 

 

M08 – PROGI LIMITÓW  
(LIMn, n=1..8) 

Jed.  Domy

ś

l. 

Zakres

 

M08 – LIMIT TRESHOLDS
(LIMn, n=1..8) 

UoM 

Default 

Range

P08.n.01 

Pomiar 

OFF OFF- (pomiary)

P08.n.01

Reference measure

 

OFF OFF- (measures)

P08.n.02 

Funkcja 

Max Max 

– Min – Min+Max

P08.n.02

Function

 

Max Max 

– Min – Min+Max

P08.n.03 

Próg najwy

ż

szy 

0 -9999 

- +9999

P08.n.03

Upper threshold

 

0 -9999 

- +9999

P08.n.04 

Mno

ż

nik 

x1 /100 

– x10k

P08.n.04

Multiplier 

 

x1 /100 

– x10k

P08.n.05 

Opó

ź

nienie s

0.0 

– 600.0

P08.n.05

Delay s 

0.0 

– 600.0

P08.n.06 

Próg najni

ż

szy 0 

-9999 

- +9999

P08.n.06

Lower threshold 

 

-9999 - +9999

P08.n.07 

Mno

ż

nik x1 

/100 

– x10k

P08.n.07

Multiplier  

x1 

/100 

– x10k

P08.n.08 

Opó

ź

nienie s

0.0 

– 600.0

P08.n.08

Delay s 

0.0 

– 600.0

P08.n.09 

Normalny status 

OFF 

OFF-ON

P08.n.09

Normal status

 

OFF 

OFF-ON

P08.n.10 

Blokada (pami

ęć

OFF OFF-ON

P08.n.10

Latch

 

OFF OFF-ON

Uwaga: To menu podzielone jest na 8 cz

ęś

ci, ka

ż

da dla jednego progu limitów  

LIM1..8 
P08.n.01 

– Definiuje który z pomiarów miernika musi by

ć

 porównywany do limitów. 

 

P08.n.02 

– Definiuje funkcj

ę

 dla progu limitów. Mo

ż

e by

ć

Max 

= LIMn jest aktywowany kiedy pomiar jest wy

ż

szy ni

ż

 ustawiony w P08.n.03.  

P08.n.06 jest progiem kasowania. 

Min

 =  LIMn jest aktywowany kiedy pomiar jest ni

ż

szy ni

ż

 ustawiony P08.n.06.  

P08.n.03 jest progiem kasowania. 

Min+Max

 =  LIMn jest aktywowany kiedy pomiar jest wy

ż

szy ni

ż

 ustawiony P08.n.03 

lub ni

ż

szy ni

ż

 ustawiony w P08.n.06. 

P08.n.03 i P08.n.04

 – U

ż

ywany jest do definiowana najwy

ż

szego progu, który sk

ł

ada 

si

ę

 z ustawionej warto

ś

ci w P08.n.03 i mno

ż

nika z P08.n.04. 

P08.n.05

 – Opó

ź

nienie zadzia

ł

ania dla progu najwy

ż

szego. 

P08.n.06, P08.n.07, P08.n.08

 – Jak powy

ż

ej, ale dla progu najni

ż

szego. 

P08.n.09

 – Pozwala na inwersje statusu limitu LIMn. 

P08.n.10 

 

Definiuje czy

 

po zadzia

ł

aniu dla danego progu nale

ż

y dokona

ć

 kasowania 

r

ę

cznie (ON) lub czy kasowanie ma by

ć

 wykonane automatycznie (OFF).

 

Note: this menu is divided into 8 sections, for limit thresholds LIM1..8
 
P08.n.01 

– Defines which measurement of the multimeter must be compared with 

limits. 

P08.n.02 

– Function of the limit threshold. It can be: 

Max 

= LIMn active when the measurement is higher than P08.n.03.  P08.n.06 is 

the reset threshold.. 

Min

 =  LIMn active when the measurement is lower than P08.n.06.  P08.n.03 is 

the reset threshold. 

Min+Max

 =  LIMn active when the measurement is higher than P08.n.03 or is 

lower than P08.n.06. 

P08.n.03 e P08.n.04

 - Used to define the upper threshold, that is made of the 

value set in P08.n.03 multiplied by P08.n.04. 

P08.n.05

 - Trip delay on upper threshold. 

P08.n.06, P08.n.07, P08.n.08

 - Like above, referred to lower threshold. 

P08.n.09

 - Allows to invert the status of the limit LIMn. 

P08.n.10 

- Defines if the threshold remains latched and thus needs to be reset 

manually (ON) or if it is reset automatically (OFF). 

 

M09 – ALARMY  

(ALAn, n=1..8) 

Domy

ś

l. 

Zakres

 

M09 – ALARMS 

(ALAn, n=1..8) 

Default 

Range

P09.n.01 

Ź

ród

ł

o alarmów 

OFF 

OFF-LIMx-INPx-BOOx

P09.n.01

Alarm source

OFF 

OFF-LIMx-INPx-BOOx

P09.n.02 

Numer kana

ł

u (x) 

1-8

P09.n.02

Channel number (x)

1-8

P09.n.03 

Blokada (pami

ęć

) OFF 

OFF-ON

P09.n.03

Latch

OFF OFF-On

P09.n.04 

Priorytet Bassa 

Niski-wysoki

P09.n.04

Priority

Low Low-High

P09.n.05 

Tekst 

ALAn (tekst 

– 16 znaków)

P09.n.05

Text

ALAn (Text 

– 16 char)

Summary of Contents for DMG700

Page 1: ...t use abrasives liquid detergents or solvents Spis tre ci Strona Wprowadzenie 2 Opis 2 Funkcje przycisk w 2 Wizualizacja odczyt w 3 Tabela wy wietlanych stron 4 Nawigacja po stronach 5 Liczniki energi...

Page 2: ...NN N i WN Teksty pomiar w ustawie i wiadomo ci w 5 j zykach Pomiar 160 parametr w elektrycznych Szyna do pod czenia maksymalnie 4 modu w EXP Zaawansowane programowanie funkcji WEJ WYJ Pomiary metod TR...

Page 3: ...not shown For every page the key allows to rotate through several sub pages for instance to show the highest lowest peak for the selected readings The sub page viewed is indicated in the status bar on...

Page 4: ...ne je li funkcje kt re maj pokazywa nie s w czone Na przyk ad je li aden z alarm w nie zosta zdefiniowany to strona Alarm w nie b dzie pokazywana Table of display pages Selection with and Selection wi...

Page 5: ...osiada dost p do Menu komend Energy meters page The Energy meters page shows the following meters simultaneously o active energy Imported and exported o reactive energy imported and exported inductive...

Page 6: ...trzy razy Je li natomiast ustawimy dzielnik na 10 to warto pokazana na wy wietlaczu a oznaczona jako 1 b dzie po zliczeniu 10 impuls w na wej ciu Przy kombinacji mno nika i dzielnika mo na uzyska pra...

Page 7: ...Access point to the commands menu where the authorised user can execute some clearing restoring actions Has o dost pu Has o u ywane jest do w czania lub wy czania dost pu do menu ustawie i komend We...

Page 8: ...Modu y komunikacji o Modu y cyfrowych WEJ WYJ By pod czy modu rozszerze o Nale y od czy zasilanie DMG700 i zdemontowa 8 polowy blok zacisk w o Nale y zdj os on ochronn otworu wej ciowego modu u o Nale...

Page 9: ...ane do tego menu Menu ustawie dotycz ce modu w rozszerze s zawsze dost pne nawet kiedy modu y nie s fizycznie pod czone Ze wzgl du na to e mo na doda wi cej ni jeden modu tego samego typu na przyk ad...

Page 10: ...NP1 is the first input terminal of the leftmost module while the subsequent inputs will be named INP2 INP3 and so on The DMG700 supports a maximum of 8 digital inputs and 8 outputs that will thus be n...

Page 11: ...nie i ostateczny rezultat to jest status wybranej zmiennej Boole a Boolean logic BOO It is possible to create max 8 internal variables named BOO1 8 whose status depends on the Boolean logic combinatio...

Page 12: ...l be the info symbol If instead the alarm must indicate a more critical situation then setting its priority to High the message will be displayed with the Warning icon and when the alarm becomes activ...

Page 13: ...n General counters M11 ENERGY PULSING PULn Energy pulse count M12 BOOLEAN LOGIC BOOn Boolean logic variables M13 INPUTS INPn Digital inputs M14 OUTPUTS OUTn Digital outputs M15 USER PAGES PAGn User de...

Page 14: ...secondary winding rated current For DMG700 fixed to 5A P01 03 System rated voltage Leaving to Aut the multimeters automatically adapts bar graph full scale P01 04 Set to ON if VT are used If set to OF...

Page 15: ...ction Bus Like fixed mode but the integration intervals are started by communication messages on the serial bus P04 02 Average readings integration time used for active reactive and apparent power P04...

Page 16: ...oM Default Range P08 n 01 Pomiar OFF OFF pomiary P08 n 01 Reference measure OFF OFF measures P08 n 02 Funkcja Max Max Min Min Max P08 n 02 Function Max Max Min Min Max P08 n 03 Pr g najwy szy 0 9999 9...

Page 17: ...ement of the counter on rising edge It can be the power on of the multimeter ON the overcoming of a limit threshold LIMx the activation of an external input INPx one logic combination BOOx P010 n 02 N...

Page 18: ...f wrong phase sequence LIMx BOOx ALAx PULx REMx Output linked to the status of the programmed variable Allows to connect the status of an output to the status of a limit threshold a Boolean variable a...

Page 19: ...k proper wiring of the DMG See wiring test chapter Once the required command has been selected press to execute it The device will prompt for a confirmation Pressing again the command will be executed...

Page 20: ...vervoltage category 3 Wysoko 2000m Altitude 2000m Napi cie izolacji Insulation voltage Znamionowe napi cie izolacji Ui 690V Rated insulation voltage Ui 690V Znamionowy impuls napi cia wytrzymywanego U...

Page 21: ...cznych nale y zapozna si ze schematami pod cze w odpowiednim rozdziale i wymaganiami podanymi w tabeli danych technicznych Kiedy pod czenie jest kompletne mo na zamontowa os ony zacisk w dostarczone r...

Page 22: ...ENT S2 S1 S2 I2 S1 I3 A O D TA1 Pod czenie 3 fazowe w uk adzie ARONA bez przewodu neutralnego ARON connection 3 phase without neutral P01 07 L1 L2 L3 Pod czenie 3 fazowe w uk adzie ARONA bez przewodu...

Page 23: ...owe napi cia 1A szybki 2 Zaciski S2 s po czone wewn trz NOTES 1 Recommended fuses Aux supply and measure inputs voltage 1Amp Fast 2 S2 terminals are internally interconnected Rozmieszczenie zacisk w T...

Reviews: