DESCRIPTION
– Flush-mount housing, 96x96mm
– Graphic LCD display, 128x80 pixels, white backlight, 4 levels of grey
– 4 keys for viewing and setting
– Easy and fast navigation
– Compatible with LV, MV, HV applications
– Texts for measurements, setup and messages in 5 languages
– Reading of more than 160 electrical parameters
– Expansion bus for maximum 4 plug-in modules EXP series
– Advanced programmable I/O functions
– True RMS measurements
– Continuous (gapless) sampling
– High accuracy
– Sealable terminal covers
– Settings lock through sealable dip-switch.
KEYBOARD FUNCTIONS
MENU key
- Used to enter or exit from viewing and setting menus.
and
keys
- Used to scroll display pages, to select among possible choices and to modify settings (increment-decrement).
key
- Used to rotate through sub-pages, to confirm a choice, to switch between viewing modes.
MEASUREMENT VIEWING
– The
and
keys allow to scroll the pages of viewed measurements one by one. The page being viewed is written in the title bar.
– Some of the readings may not be shown, depending on the programming and the wiring of the device (for instance, if programmed-wired for a three-phase without neutral system, L-N voltage page is not shown).
– For every page, the
key allows to rotate through several sub-pages (for instance to show the highest/lowest peak for the selected readings).
– The sub-page viewed is indicated in the status bar on the bottom of the display by one of the following icons:
•
IN = Instantaneous value
- Actual instantaneous value of the reading, shown by default every time the page is changed.
•
HI = Highest peak
- Highest peak of the instantaneous value of the relative reading. The HIGH values are stored and kept even when auxiliary power is removed. They can be cleared using the dedicated
command (see commands menu).
•
LO = Lowest peak
- Lowest value of the reading, stored from the time the DMG is powered-on. It is resetted using the same command used for HI values.
•
AV = Average value
- Time-integrated value of the reading. Allows showing measurements with slow variations. See integration menu in setup chapter.
•
MD = Maximum Demand
- Maximum peak of the integrated value. Stored in non-volatile memory and it is resettable with dedicated command.
•
GR = Graphic bars
- Shows the measurements with graphic bars.
Example of display page with numeric indication
1 - Unit of measure
2 - Measurement
3 - Title bar
4 - Phase indication
5 - Sub-page indication
1 - Unit of measure
2 - Measurement
3 - Phase indication
4 - HI-LO markers
Example of display page with bar-graphs
– The user can define to which page and sub-page the display must return to after a period of time has elapsed without any keystroke.
– If needed, it is possible to set the multimeter so that the display will remain always in the position in which it has been left.
– To set these functions see menu M02 – Utility.