background image

 
When the device is out of power, one of the three green led lights starts blinking. The led 
turns off after the charging process has started. 
If PERFECT SKIN is connected to mains when is still turned on, it will turn off automatically. 
 
USE 

 

OPERATION TEST 
Whenever you want to use PERFECT SKIN, you have to verify it works correctly by carrying 
out the following test. 
1. To test the device, place it with the lens down and in contact with any part of the body, 
except for the eyes, for example with hands or legs (the photodiode enables the infrared 
laser beam and the pointing red led at a distance shorter than 3 cm from any surface or 
part). 
2. Turn on the device by holding the power button  pressed for few seconds.  The red led 
will blink and the FACE green led will turn on by default.   
3. The red led is blinking (laser emission in standby mode). Place a hand at a distance 
shorter than 3 cm from the device’s lens (it is better there is a contact), thus the red led will 
emit a fixed light (laser emission in progress). 
4. If the operation test has been successful, you can proceed with the desired treatment.  
 
When the device is turned on, it will be in FACE mode by default. If you prefer to go to the 
BODY mode hold the power button pressed until the green led of the desired program will 
turn on. If you prefer to go to the CREAM mode hold again the power button pressed until 
the green led of the desired program will turn on. To go back to the FACE treatment hold 
again the button pressed by turning off the device and continuing pressing it until it will 
turn on. 
 
FACE TREATMENT 

-

 

To obtain a drainage effect and provide the skin with a bright appearance; 

-

 

To remove wrinkles and obtain a face anti-aging effect. 

 

The FACE treatment must be performed on clean, dry and without make-up  face  skin. 
Please remove any jewel or dress that may be reflective to the area to be treated or to 
the adjacent area. Open the box containing the PERFECT SKIN LASER, remove the device 
case and press the power button until the green light led of the FACE program will turn on 
by making sure to never direct the lens, and thus the Laser beam and the LED, toward the 
eyes. Before performing this program we suggest to wear the supplied protective goggles. 
Put the device lens in contact with face  skin by keeping it as much perpendicular as 
possible. The treatment is performed by treating the hemiface (half face) at a time, it must 
start from the lower part of the face, preferably, the chin, and then slowly you must move 
to the upper part (forehead). It is important to treat the whole half part of the face trying 
to distribute the LED and infrared Laser energy homogeneously to the entire surface.  Each 

Summary of Contents for Perfect Skin

Page 1: ...N OF THE DEVICE AND ACCESSORIES WARNINGS AND CONTROLS CONTROL PANEL SIGNALLING FEATURES DEVICE CHARGE USE OPERATION TEST FACE TREATMENT BODY TREATMENT CREAM TREATMENT CREAM CONVEYANCE MAINTENANCE PROB...

Page 2: ...will have to show a purchase document attesting the date of purchase the product description model and serial number In case you bought it from a retailer you will have to show a document indicating...

Page 3: ...age on the rating plate of the charger and in the Technical features of this manual correspond to those of the mains electricity available Do not use the device during the charging process or once it...

Page 4: ...ser Means of fixation metal and plastics plates are not a contraindication to the use of the laser During the treatment with PERFECT SKIN it is recommended not to wear any jewel dress or accessory tha...

Page 5: ...e black cloth case user manual protective goggles for FACE treatment WARNINGS AND CONTROLS 1 Lens to focus the soft laser 2 Red colored guide light for the indication of the operating device 3 Laser d...

Page 6: ...y chargers than the one supplied The use of any different battery charger might damage the device and invalidate the warranty Once connected the battery charger to the device before plugging it to mai...

Page 7: ...l the green led of the desired program will turn on If you prefer to go to the CREAM mode hold again the power button pressed until the green led of the desired program will turn on To go back to the...

Page 8: ...y jewel or dress that may be reflective to the area to be treated or to the adjacent area Open the box containing the PERFECT SKIN LASER remove the device case and press the power button until the gre...

Page 9: ...cular as possible The treatment is performed by treating one area of the hemiface half face or of the body for example the right thigh at a time It must start form the lower part of it moving it slowi...

Page 10: ...d the device emits a triple warning acoustic signal Press the Program button so as to turn off the device and not unnecessarily discharge battery MAINTENANCE For safety reasons before carrying out any...

Page 11: ...Ah Supply voltage 3 7 V Size 48x30x7 mm Weight 19 5 gr Characteristics of the body Material ABS Shape Rigid cylindrical tube Size Diameter 37mm Height 157mm Color PANTONE 386 yellow lime green Charact...

Page 12: ...tical density at a distance from 1 23 to 0 5 m at a distance between 0 70 to 1 m Peak power for single diode 25 W Average power per laser diode 25 mW LED diode light intensity 30 mcd Led to indicating...

Page 13: ...liability for the use of this product LOWE srl reserves the right to change the contents of this manual without obligation to notify the revisions LABELS Attention laser beam Dispose of the device as...

Page 14: ...lse duration Pulse duration CONTACTS LOWE S r l Via degli Abeti 92 61122 Pesaro Ph 0721 404772 Fax 0721 1633123 For assistance customercare lo we com For general information info lo we com www lo we c...

Page 15: ...DECLARATION OF CONFORMITY...

Reviews: