background image

©2021 Lowell Manufacturing Co. | X-Rev.10-21-21 

  

Chapter 1. Important Safety Warnings  

Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly 

and carefully read the following instructions before installing the unit. Do not operate this unit before reading 
through all safety information and operating instructions carefully.  

• 

Do not try to repair the unit yourself, contact your local supplier or your warranty will be void.  

• 

To eliminate any overheating of the battery box, keep all ventilation openings free from obstruction 
and do not place any foreign objects on top of the battery bank. Keep the battery box 20m away from 
the wall.  

• 

Make sure the battery box is installed within the proper environment as specified. (0-40°C and 30-
90% non-condensing humidity)  

• 

Do not install the battery box under direct sunlight. Your warranty will be void if the batteries fail 
due to overheating.  

• 

This battery box is not designed for use in dusty, corrosive, and salty environment.  

• 

The warranty for this battery bank will be void if water or other liquid is spilt or poured directly onto 
the battery box. Similarly, we do not warrant any damage to the battery box if foreign objects are 
deliberately or accidentally inserted into the battery box enclosure.  

• 

The battery will discharge naturally if the system is unused for a period.  

• 

It should be recharged every 2-3 months if unused. If this is not done, then the warranty will be null 
and void. During normal operation, the batteries will be automatically remained in charged condition.  

• 

Servicing of batteries should be performed or supervised by trained personnel with knowledge of 
batteries and the required precautions.  

• 

When replacing batteries, it is necessary to replace All batteries with the same quantity,  
type & capacity.  

• 

CAUTION- Do not dispose of battery or batteries in a fire. The battery may explode.  

• 

CAUTION - Do not open or mutilate the batteries. The electrolyte from the batteries is toxic and 
harmful to the skin and eyes.  

• 

CAUTION - Risk of Electric Shock - Hazardous voltage may exist between battery terminals and 
ground. Test before touching with bare hands.  

• 

CAUTION -A battery can present a risk of electrical shock and high short circuit current.  
The following precaution should be observed when working on batteries:  

a.

 

Remove watches, rings, or other metal objects.  

b.

 

Use tools with insulated handles.  

b.

 

Wear rubber gloves and boots.  

c.

 

Do not lay tools or metal parts on top of batteries.  

d.

 

Disconnect charging source prior to connecting or disconnecting battery terminals.  

• 

Do not plug or unplug the battery connector if UPS works in DC (discharging) mode.  

  

  

  

  

Summary of Contents for UPS-XBPA Series

Page 1: ...2021 Lowell Manufacturing Co X Rev 10 21 21 1 UPS XBPA Series Expansion Battery Pack Models UPS XBPA 36 UPS XBPA 36E UPS XBPA 48 UPS XBPA 72 User Installation Manual power TM...

Page 2: ...1 2 Table of Contents 1 Important Safety Warnings 3 2 Product Overview Setup 4 a Rack installation 5 b Tower installation 6 c Connecting UPS with another Battery Box 6 3 Type of Battery Required 7 4 B...

Page 3: ...deliberately or accidentally inserted into the battery box enclosure The battery will discharge naturally if the system is unused for a period It should be recharged every 2 3 months if unused If thi...

Page 4: ...UPS or 2nd battery box 2 DC breaker Battery over current protection breaker 3 External battery numbers detection port detects the numbers of connected batteries 2 2 Installation and setup with UPS Un...

Page 5: ...in accordance with the unit s working specifications to avoid overheat and excessive moisture Do not place the unit in a dusty or corrosive environment or near flammable objects This unit is not desi...

Page 6: ...2021 Lowell Manufacturing Co X Rev 10 21 21 6 Tower installation Connecting with UPS and another Battery Box Follow below installation chart to connect with UPS and another battery box with included...

Page 7: ...gned to operate with the following types of batteries UPS XBPA 36 36V 18Ah Version 6 pieces of 12V 9Ah 3 3 batteries UPS XBPA 36E 36V 36Ah Version 12 pieces of 12V 9Ah 3 3 3 3 batteries UPS XBPA 48 48...

Page 8: ...1 Open the package and place the battery box on a horizontal plane Step 2 Remove the removable front panel part by pulling it from the lower extremity Step 3 Remove the fixed part of the front panel b...

Page 9: ...the same procedure on the right side of battery box Step 7 Connecting all batteries following the wiring diagram shown in chapter 5 Step 8 Secure all batteries inside with the metal plate Note To ins...

Page 10: ...he lower extremity Step 3 Remove the fixed part of the front panel by removing the 2 screws Step 4 Remove the metal top cover of the battery box by unscrewing 8 screws present on the two sides 4 on th...

Page 11: ...he same procedure on the right side of battery box Step 7 Connecting all batteries following the wiring diagram shown in chapter 5 Step 8 Secure all batteries of the 1st and 2nd strings inside with th...

Page 12: ...e lower extremity Step 3 Remove the fixed part of the front panel by removing the 2 screws Step 4 Remove the metal top cover of the battery box by unscrewing 8 screws present on the two sides 4 on the...

Page 13: ...the same procedure on the right side of battery box Step 7 Connecting all batteries following the wiring diagram shown in chapter 5 Step 8 Secure all batteries inside with the metal plate Note To ins...

Page 14: ...e lower extremity Step 3 Remove the fixed part of the front panel by removing the 2 screws Step 4 Remove the metal top cover of the battery box by unscrewing 8 screws present on the two sides 4 on the...

Page 15: ...the same procedure on the right side of battery box Step 7 Connecting all batteries following the wiring diagram shown in chapter 5 Step 8 Secure all batteries inside with the metal plate Note To ins...

Page 16: ...Rev 10 21 21 16 Chapter 5 Wiring Diagrams Note The cable connection from external battery connector to PCB is already present inside the battery box All the other cable connection should be followed b...

Page 17: ...2021 Lowell Manufacturing Co X Rev 10 21 21 17 5 2 UPS XBPA 36E...

Page 18: ...2021 Lowell Manufacturing Co X Rev 10 21 21 18 5 3 UPS XBPA 48...

Page 19: ...2021 Lowell Manufacturing Co X Rev 10 21 21 19 5 4 UPS XBPA 72...

Reviews: