Lowell Manufacturing Company | UPS6LI Series 

Page 4 

4.

 

Installation & Initial Startup 

Note: 

Before installation, inspect the unit and packaging to make sure that nothing inside has been damaged.

 

Connect UPS to Utility and Charging

 

Before the initial use of the UPS, plug the UPS input cord into a wall outlet and turn the UPS on by pressing the 

Power switch on the back of the UPS. For best results, the batteries in the UPS should be charged for at least 8 

hours before use. The UPS charges its battery while it is connected to AC utility power and powered on. 

Connecting the Loads

 

Plug the loads to be supported by the UPS into the output receptacles on the front of the UPS. Simply turn the 

power switch on the UPS on and the devices connected to the UPS will be protected by the UPS unit. 

Turn UPS ON / OFF

 

To turn the UPS unit on, press the power button on the UPS and hold for three seconds. To turn the UPS unit off, 

press the power button and hold for one second. 

Connecting Local Monitoring Software (optional)

 

If it is desired to use the Local Monitoring Software, and if your UPS is equipped with USB communications, connect 

a USB cable from your computer to the UPS, and install the software from the CD. 

 

5.

 

Indicators & Alarm Conditions 

Condition

 

Visual Indicator

 

Alarm

 

AC mode 

LED illuminated 

No Audible Alarm 

Battery mode 

LED flashes every 10 seconds 

Audible Alarm sounds every 10 
seconds 

Low battery mode 

LED flashes every 1 second 

Audible Alarm sounds every 1 
second 

Fault 

LED is illuminated 

Audible Alarm is continuous 

Alarm for over temperature 
protection 

LED flashes every 0.5 seconds 

No Audible Alarm 

   

 

 

Summary of Contents for UPS6LI Series

Page 1: ...UPS6LI Series Compact Standby UPS with Lithium Battery Models UPS6LI 350 UPS6LI 600 User Installation Manual 2022 Lowell Manufacturing Company Rev 4 8 20...

Page 2: ...ntents 1 Package Contents 3 2 Product Introduction 3 3 Product Overview 3 4 Installation Initial Startup 4 5 Indicators Alarm Conditions 4 6 Important Safety Instructions save 5 7 Troubleshooting 7 8...

Page 3: ...it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so...

Page 4: ...the UPS on and the devices connected to the UPS will be protected by the UPS unit Turn UPS ON OFF To turn the UPS unit on press the power button on the UPS and hold for three seconds To turn the UPS u...

Page 5: ...and load prior to installing or maintaining the battery f Remove battery grounds during installation and maintenance to reduce likelihood of shock Remove the connection from ground if any part of the...

Page 6: ...g Company UPS6LI Series Page 6 The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and follow up maintenance of th...

Page 7: ...he load from the output of the UPS UPS fault Return the unit for service Alarm continuously sounds when the AC input is normal Battery defect Replace the battery with the same type of battery Charging...

Page 8: ...chable 5 15P to C13 Receptacles 3 5 15R ENVIRONMENT Temperature 32 104 F 0 40 C Humidity 0 90 Altitude 11 500 ft above sea level COMMUNICATIONS INTERFACE Standard communications USB Interface includin...

Page 9: ...tion and if possible help solve the problem over the phone In the event that the unit requires factory service the representative will issue you a Return Material Authorization number RMA If you are r...

Page 10: ...void if a the equipment is repaired or modified by anyone other than Lowell Manufacturing Company or a Lowell Manufacturing Company approved third party b the equipment is damaged by the customer is i...