Lowell Manufacturing Company | UPS6LI Series 

Page 5 

6.

 

Important Safety Instructions: (Save These Instructions) 

– This manual contains important instructions for the UPS6LI Series UPS that should be followed during 

installation and maintenance of the UPS

 

CAUTION!  (UPS  having  Internal  Batteries):

  Risk  of  electrical  shock  –  Hazardous  live  parts  inside  this  unit  are 

energized from the battery supply even when the input AC power is disconnected. 

CAUTION! (No User serviceable Parts): 

Risk of electrical shock, do not remove cover. No user serviceable parts 

inside. Refer servicing to qualified service personnel. 

CAUTION!  (Non-isolated  Battery  supply): 

Risk  of  electric  shock,  battery  circuit  is  not  isolated  from  AC  input, 

hazardous voltage may exist between battery terminals and ground. Test before touching. 

WARNING!

 Unit intended for installation in a controlled environment. 

CAUTION!

 Do not dispose of batteries in a fire, the battery may explode. 

CAUTION!

 Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes. 

CAUTION: 

A battery can present a risk of electrical shock and high short-circuit current. Contact with any part of 

a grounded battery can result in electrical shock. The following precautions should be observed when working on 
batteries: 

a)

 

Remove watches, rings, or other metal objects. 

b)

 

Use tools with insulated handles. 

c)

 

Wear rubber gloves and boots. 

d)

 

Do not lay tools or metal parts on top of batteries. 

e)

 

Disconnect charging source and load prior to installing or maintaining the battery. 

f)

 

Remove battery grounds during installation and maintenance to reduce likelihood of shock. 
Remove the connection from ground if any part of the battery is determined to be grounded. 

EN 62040-2,C2: 

WARNING: 

This is a category C2 UPS product. In a residential environment, this product may cause radio 

interference, in which case the user may be required to take additional measures. 

FCC Notice: Class A 
NOTE:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to correct 
the interference at his own expense. 

WARNING: 

Changes or modifications not expressly approved by the party responsible for compliance could 

void the user’s authority to operate the equipment. 

To reduce the risk of electric shock, disconnect the UPS from the main supply before installing a computer inter- 

face signal cable. Reconnect the power cord only after signaling interconnections have been made. 

Servicing  of  batteries  should  be  performed  or  supervised  by  personnel  with  knowledge  of  batteries  and  the 

required precautions. Keep unauthorized personnel away from batteries.  

Summary of Contents for UPS6LI Series

Page 1: ...UPS6LI Series Compact Standby UPS with Lithium Battery Models UPS6LI 350 UPS6LI 600 User Installation Manual 2022 Lowell Manufacturing Company Rev 4 8 20...

Page 2: ...ntents 1 Package Contents 3 2 Product Introduction 3 3 Product Overview 3 4 Installation Initial Startup 4 5 Indicators Alarm Conditions 4 6 Important Safety Instructions save 5 7 Troubleshooting 7 8...

Page 3: ...it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so...

Page 4: ...the UPS on and the devices connected to the UPS will be protected by the UPS unit Turn UPS ON OFF To turn the UPS unit on press the power button on the UPS and hold for three seconds To turn the UPS u...

Page 5: ...and load prior to installing or maintaining the battery f Remove battery grounds during installation and maintenance to reduce likelihood of shock Remove the connection from ground if any part of the...

Page 6: ...g Company UPS6LI Series Page 6 The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and follow up maintenance of th...

Page 7: ...he load from the output of the UPS UPS fault Return the unit for service Alarm continuously sounds when the AC input is normal Battery defect Replace the battery with the same type of battery Charging...

Page 8: ...chable 5 15P to C13 Receptacles 3 5 15R ENVIRONMENT Temperature 32 104 F 0 40 C Humidity 0 90 Altitude 11 500 ft above sea level COMMUNICATIONS INTERFACE Standard communications USB Interface includin...

Page 9: ...tion and if possible help solve the problem over the phone In the event that the unit requires factory service the representative will issue you a Return Material Authorization number RMA If you are r...

Page 10: ...void if a the equipment is repaired or modified by anyone other than Lowell Manufacturing Company or a Lowell Manufacturing Company approved third party b the equipment is damaged by the customer is i...