LIMITED WARRANTY

Lowell Manufacturing Company warrants Lowell UPS equipment, when properly applied and operated within specified 
conditions, against faulty materials or workmanship for a period of 

three years for UPS8 Series products

 from the date 

of purchase . Lowell Manufacturing Company warrants 

internal batteries for a period of three years 

from the date of 

purchase . For equipment sites within the United States and Canada, this warranty covers repair or replacement, at the sole 
discretion of Lowell Manufacturing Company . The customer is responsible for the costs of shipping the defective product to 
Lowell Manufacturing Company . Lowell Manufacturing Company will pay for ground shipment of the repaired or replacement 
product . This warranty applies only to the original purchaser .

If equipment provided by Lowell Manufacturing Company is found to be 

Dead-on-Arrival (DOA)

, Lowell Manufacturing 

Company will be responsible for the costs of shipping product to and returning equipment from the customer in a timely 
manner as agreed to with the customer, once the customer has requested and received a 

Return Material Authorization 

(RMA) 

number . DOA equipment is defined as equipment that does not properly function according to user documentation 

when initially received and connected in conjunction with proper procedures as shown in the user documentation or via 
support provided by Lowell Manufacturing Company personnel or authorized agents .

This warranty shall be void if (a) the equipment is repaired or modified by anyone other than Lowell Manufacturing Company 
or a Lowell Manufacturing Company approved third party; (b) the equipment is damaged by the customer, is improperly used 
or stored, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications; or 
(c) the equipment has been used or stored in a manner contrary to the equipment’s operating manual, intended use or other 
written instructions . Any technical advice furnished by Lowell Manufacturing Company or a Lowell Manufacturing Company 
authorized representative before or after delivery with regard to the use or application of Lowell Manufacturing Company 
equipment is furnished on the basis that it represents Lowell Manufacturing Company’s best judgment under the situation and 
circumstances, but it is used at the recipient’s sole risk .

EXCEPT AS STATED ABOVE, Lowell Manufacturing Company DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, 
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .

EXCEPT AS STATED ABOVE, IN NO EVENT WILL Lowell Manufacturing Company BE LIABLE FOR DIRECT, INDIRECT, 
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Lowell Manufacturing Company 
UPS8 Series EQUIPMENT, including but not limited to, any costs, lost profits or revenue, loss of equipment, loss of use 
of equipment, loss of software, loss of data, cost of substitutes, or claims by third parties . Purchaser’s sole and exclusive 
remedy for breach of any warranty, expressed or implied, concerning Lowell Manufacturing Company equipment, and the only 
obligation of Lowell Manufacturing Company under this warranty, shall be the repair or replacement of defective equipment, 
components, or parts; or, at Lowell Manufacturing Company’s sole discretion, refund of the purchase price or substitution of 
an equivalent replacement product . 

Summary of Contents for UPS8-1100

Page 1: ...UPS8 Series Pure Sine Wave Line Interactive UPS Models UPS8 1100 UPS8 1500 UPS8 2000 UPS8 2200 UPS8 3000 User Installation Manual 04 03 18...

Page 2: ...Button Operation 15 LCD Panel 15 Audible Alarms 17 Abbreviations in LCD Display 17 UPS Setting 18 Operating Mode Descriptions 21 Fault Reference Codes 22 Warning Indicators 22 TROUBLESHOOTING 23 STOR...

Page 3: ...puter to connect the UPS system to the building wiring outlet shockproof outlet Use only VDE tested CE marked power cables to connect the loads to the UPS system When installing the equipment it shoul...

Page 4: ...ries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries Remove wristwatc...

Page 5: ...connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit breaker 5 Network Fax Modem surge protection 6 Emergency power off function connector EP...

Page 6: ...UPS is shipped out from the factory without connecting battery wires Before installing the UPS follow these steps to re connect battery wires Connect Battery Wires Step 1 Remove front panel Step 2 Co...

Page 7: ...p 2 Attach the mounting brackets to the UPS CAUTION DO NOT use mounting brackets to lift the UPS brackets are only to secure it to the rack Step 3 Place UPS on the support rails and secure in place wi...

Page 8: ...and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through the PC NOTE USB port and RS 232 port ca...

Page 9: ...er on the UPS NOTE The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 8 Install software For opt...

Page 10: ...UTION Consider all warnings cautions and notes before replacing batteries Note Upon battery disconnection equipment is not protected from power outages Step 1 Remove front panel Step 2 Disconnect batt...

Page 11: ...Lowell UPS8 Series Manual Pg 11 Step 5 After replacing the batteries return battery box to original location screw tightly Step 6 Re connect the battery wires Step 7 Replace front panel...

Page 12: ...ect battery kit procedure two four or six battery kit listed below to assemble it TWO 2 Battery Kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals per diagram Step 3 Put assembled b...

Page 13: ...ry Kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals per diagram Step 3 Put assembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as sh...

Page 14: ...ry Kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals per diagram Step 3 Put assembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as sh...

Page 15: ...mode OFF ENTER Turn Off Press and hold this button for at least 2 seconds to turn the UPS off Confirm Selection Key Press this button to confirm selection in UPS setting mode SELECT Switch LCD Messag...

Page 16: ...y or battery voltage V output voltage Hz frequency Load Information Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuited U...

Page 17: ...w Battery Sounds every 2 seconds Overload Sounds every second Fault Continuously sounds Abbreviations in LCD Display Abbreviation Display Meaning ENA Enable DIS Disable ESC Escape ON ON OK OK EP EPO T...

Page 18: ...Programmable outlets enable default DIS Programmable outlets disable Interface Setting Setting the backup time limit in minutes from 0 999 for programmable outlets which connect to non critcal devices...

Page 19: ...99 Setting the backup time in minutes from 0 999 for general outlets on battery mode DIS Disable the autonomy limitation and the backup time will depend on battery capacity default Note When setting i...

Page 20: ...ng of parameter 2 Press the Up button to change the value to ENA to enable the programmable outlet function Then press Enter button again to confirm the setting Step 4 Press the Up button ON MUTE agai...

Page 21: ...n the input voltage is higher than the voltage regulation range but lower than high loss point the buck AVR will be activated Boost mode when AC is normal When the input voltage is lower than the volt...

Page 22: ...ery Fault Sounds every 2 seconds At this time UPS is off to remind users that something is wrong with the battery EEPROM Error Sounds every 2 seconds Battery Replacement Sounds every 2 seconds Warning...

Page 23: ...s shown as 27 and the icon is showing on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is in fault condition Contact your dealer for support Fault code is s...

Page 24: ...is case contact your dealer Storage Before storing charge the UPS at least 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the f...

Page 25: ...4 hours to 90 PHYSICAL Dimensions W x D x H 17 2 x 15 1 x 3 5 in 17 2 x 18 9 x 3 5 in 17 2 x 23 6 x 3 5 in Weight 30 5 lbs 44 7 lbs 47 4 lbs 61 7 lbs 67 1 lbs Line cord 6 ft 5 15P 6 ft 5 15P 6 ft 5 20...

Page 26: ...possible help solve the problem over the phone In the event that the unit requires factory service the representative will issue you a Return Material Authorization number RMA If you are returning th...

Page 27: ...or a Lowell Manufacturing Company approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside t...

Page 28: ...ery box if foreign objects are deliberately or accidentally inserted into the battery box enclosure The battery will discharge naturally if the system is unused for a period of time It should be recha...

Page 29: ...ws Extended stand 4 point rail kit with screws Selecting Installation Position It is necessary to select a proper environment to install the unit in order to minimize the possibility of damage to the...

Page 30: ...mounting brackets to the unit CAUTION DO NOT use mounting brackets to lift the unit brackets are only to secure it to the rack Step 3 Place unit on the support rails and secure in place with front sc...

Page 31: ...UENCE OF OPERATIONS MODEL NO UPS XBP 48 Step 1 Open the package and place the battery box on a horizontal plane Step 2 Remove the left side of the front panel by pulling it from the lower extremity St...

Page 32: ...ries inside and secure in place with hold down brackets Note To install a second string of batteries repeat the same procedure on the right side of battery box Step 9 Replace the metal top cover on th...

Page 33: ...tteries inside the unit by following the drawing below which indicates wire fastener positions for correct battery placement Note To install a second string of batteries repeat the same procedure on t...

Page 34: ...ing Diagrams NOTE The cable connection from the external battery connector to PCB is already present inside the battery box All the other cable connections should be made in accordance with the above...

Page 35: ...g 35 MODEL NO UPS XBP 72 NOTE The cable connection from the external battery connector to PCB is already present inside the battery box All the other cable connections should be made in accordance wit...

Page 36: ...se contact your dealer Storage Before storing charge the unit 4 hours Store the unit covered and upright in a cool dry location During storage recharge the battery in accordance with the following tab...

Reviews: