Technical Manual LÖWEN Dart HB8
01/2019
52
6.1.8
P10 - SEL dOr: Dormant Time-Out Programming
Dormant time-out refers to the amount of time that a game in progress can be idle (no darts thrown) before
the dart machine will reset itself, and a new game may be started. Dormant time-out can be set from 0 to 90
minutes in 15 minute steps. Factory setting: 30 minutes.
1.
Press [TEST] button on the controller board.
tSt
appears in the TEMP SCORE display.
2.
Press [GAMES] or [OPTIONS I] button until
Pr9
appears in the TEMP SCORE display.
3.
Press [OPTIONS II] button to confirm.
P01
appears in the TEMP SCORE display.
4.
Press [GAMES] or [OPTIONS I] button until
SEL dOr
appears in the player 1 – 2 display, and
P10
in
the TEMP SCORE display.
5.
Press [OPTIONS II] to confirm.
1 2
3 4
1
2
3
4
5
6
7
8
TEMP SCORE
5 6
7 8
6.
Press [GAMES] or [OPTIONS I] button to adjust dormant time-out between 0 and 90 minutes in 15
minute steps. Selecting 0 deactivates the dormant time-out.
The new dormant time-out value will be displayed in the TEMP SCORE display.
7.
Press [OPTIONS II] button to confirm.
8.
Press [PLAYER CHANGE] button to exit.