LP Morgan Installation Instructions | 9
LP Morgan Flipper Manual
The Flipper was designed by an installer, with the installer in mind. The face
panel that is supplied is 18mm undercoated MDF, and is easily removed via
six screws.
We recommend that you remove and paint this panel before fixing the Flipper
in the ceiling.
In the case of a non-plasterboard ceiling, you may choose to fabricate your own
ceiling panel (eg. from the same timber/material as the ceiling itself) to match.
The Ceiling trim we supply will leave a 2mm clearance on all sides of this
face panel.
If you choose not to use this ceiling trim, you should be aware that you will
need to allow more clearance at the front and back of the panel, because the
trajectory traced by the ceiling panel is actually wider than the ceiling trim.
For a Standard Flipper
Length
Width
Face Panel
500
450
Cutout required, if NOT using the supplied trim
508
454
Cutout required, if using the supplied trim
528
478
For a Large Flipper
Length
Width
Face Panel
600
550
Cutout required, if NOT using the supplied trim
608
554
Cutout required, if using the supplied trim
628
578
Ceiling opening