LP Morgan Installation Instructions | 9
LP Morgan Resi-Lift Manual
Installing ceiling closure
CAUTION:
• Make sure the nuts are completely tightened.
• DO NOT hang from, “ride” or pull down on the unit. This could
create a failure and cause damage and/or injury.
Check the faceplate/ceiling tile is flush with the surrounding ceiling panel and
adjust as necessary by threading the hanging rods up or down as required.
If your Resi-Lift is equipped with a ceiling plate system, it can be used as is,
or in conjunction with a square of existing ceiling tile. Please refer to diagram
below for these instructions.
Manual Installation Notes
When the Resi-Lift is in the closed position, determine the spacing from
the plate to the faceplate to allow for fitting of the projector/bracket and
ceiling tile fitting.
• Cut the all thread hanging rod to suit the spacing distance plus an additional
50mm. Screw 50mm of hanging thread up inside the baseplate
• The hanging rods should be at the shortest length possible to ensure the
ceiling faceplate assembly does not shake or interfere with the cut-out or trim,
as it returns to its closed position.
Screw the 4 rods into the base plate threaded holes (475mm centres).
Position the faceplate onto the hanging rods securing with washers and nuts
both sides of the faceplate/ceiling tile brackets.