background image

5

The manufacturer reserves the right to modify the product’s technical specifications without prior

notice. Any reproduction, even in part, is prohibited. All the illustrations in this Operator’s Manual are

non-binding.

W A R N I N G

Depending on the version you have, basic version or full version (see 
serial number on the nameplate), some protocols are not activated 
and  their  accessories  are  not  provided.  Therefore,  the  paragraphs 
describing  them  do  not  apply  to  the  basic  version  (see  the  Table 
below).

Accordingly,  the  paragraphs  describing  them  do  not  concern  this 
version (see table on the next page).

Accessories

Guardrails

Stability test chock

Articulated stool

Pads

Tablet

Summary of Contents for HUBER 360 MD

Page 1: ...this entire manual carefully before using your device LPG Systems 2014 LPG and HUBER are registered trademarks Reproduction even in part is strictly prohibited Keep this manual and the separate installation instructions for future reference GU1306 GB Indice A of 10 14 ...

Page 2: ... latest technologies with LPG s expertise You can fully appreciate the technical perfection and reliability that have made LPG Systems the leader in this field This operator s manual describes how to operate the device instructions for periodic maintenance and safety guidelines Your device should be used only by a professional who has completed the manufacturer s training provided by LPG Systems o...

Page 3: ... One HUBER 360 MD One set of guardrails One stability test chock One articulated stool Two pads One tablet One operator s manual One power cable One set of quick unpacking and set up instructions One POS display ...

Page 4: ...ending on the version you have basic version or full version see serial number on the nameplate some protocols are not activated and their accessories are not provided Therefore the paragraphs describing them do not apply to the basic version see the Table below Accordingly the paragraphs describing them do not concern this version see table on the next page Accessories Guardrails Stability test c...

Page 5: ...GNETIC COMPATIBILITY 37 2 1 Control Screen 9 2 2 Handle 10 2 3 Platform 10 2 4 Pads 11 2 5 Articulated stool Hu seat 14 2 6 Tablet 17 2 7 Guardrails 18 2 8 Stability test chock 19 3 1 Installation 21 3 2 Warning 23 3 3 Precautions 24 3 4 Warnings 25 3 5 Electromagnetic Compatibility 26 4 1 Cleaning the device 27 4 2 Identification nameplate 27 4 3 Power cord 29 1 1 Intended use 7 1 2 Presentation ...

Page 6: ... clinics by specialists and physiotherapists It is an independent device that cannot be combined with other machines It should only be used by professionals who have been specially trained by LPG Systems in its use It is not meant to be used at home HANDLE MEASURING SYSTEM PLATFORM BASE EMERGENCY STOP BUTTON TOUCHSCREEN INTERFACE BLOWER MEASURING SYSTEM The unit can only operate if its power cable...

Page 7: ...8 1 DEVICE DESCRIPTION D E V I C E D E S C R I P T I O N INDICATOR POWER ON CIRCUIT BREAKER POWER SWITCH NO 1 TURN ON FIRST CIRCUIT BREAKER POWER SWITCH NO 2 TURN ON SECOND ...

Page 8: ...9 2 CONTROL SCREEN C O N T R O L S A N D A C C E S S O R I E S ETHERNET JACK USB PORT AUDIO PORT TOUCHSCREEN POWER INDICATOR ...

Page 9: ...1 0 2 HANDLE PLATFORM C O N T R O L S A N D A C C E S S O R I E S PLATFORM LEVEL POSITIONING MARKERS RECESSED FOR POSITIONING ACCESSORIES ...

Page 10: ...C C E S S O R I E S The HUBER 360 MD may come with two Pads that can be positioned on the platform FOOT ORIENTATION ANGLE MARKER PAD ROTATION ANGLE MARKER Overview Underside ORIENTATION MARKER ON THE UPPER MOVEABLE SIDE POSITIONING PINS ...

Page 11: ...uld be performed when the device is powered off W A R N I N G The Pads can be positioned on the platform in the positioning holes To position the Pads on the platform you will need to align the positioning pins on the Pads with the suitable positioning holes POSITIONING THE PADS POSITIONING HOLE ...

Page 12: ...ng it downwards photo 1 and then rotate the upper part of the Pads so that the marker lines up with the proper degree of tilt photo 2 ORIENTATION OF FOOTINGS ON THE PAD The orientation of the footing can vary 0 to 90 with respect to the inclination of the Pad To do this simply position the footing to the desired angle FOOTING DIRECTION ORIENTATION OF THE PADS PAD ROTATION DIRECTION MARKER ON THE M...

Page 13: ...LATED STOOL Your HUBER 360 MD may come with an articulated stool that can be positioned on the platform SEAT ARTICULATED STOOL TILT ANGLE MARKER TILT WHEEL ADJUSTMENT BASE POSITIONING PINS Overview Underside LOCK NUTS PNEUMATIC JACK HEIGHT ADJUSTMENT HANDLE ...

Page 14: ...C C E S S O R I E S ARTICULATED STOOL CONT To position the articulated stool on the platform you will need to align the positioning pins on the articulated stool with the suitable positioning holes POSITIONING THE ARTICULATED STOOL ...

Page 15: ... button until the tool is lodged into the recess as shown in the photos below Ensure that the articulated stool is properly locked before use All operations in this section should be performed when the device is powered off W A R N I N G TILT ANGLE TILT MARKER The articulated stool can tilt from 0 to 15 To do this turn the articulated stool s adjustment knob to set the marker to the desired tilt T...

Page 16: ...e with a tablet that lets you access the HUBER 360 application This application will allow you to create user profiles and download exercises to the machine It also allows you to control certain settings remotely Details about how to use the application are provided when you open it ...

Page 17: ... C O N T R O L S A N D A C C E S S O R I E S GUARDRAILS ATTACHMENT MECHANISMS The HUBER 360 MD may come with two guardrails attached to the machine These guardrails are meant to make the machine easier to use Overview ...

Page 18: ...POSITIONING PINS POSITIONING PINS STABILITY TEST CHOCK The HUBER 360 MD comes with a stability test chock that can be positioned on the platform Overview Underside C O N T R O L S A N D A C C E S S O R I E S ...

Page 19: ...TIONING THE STABILITY TEST CHOCK The stability test chock can be positioned on the platform using the positioning holes shown in the photo below POSITIONING HOLE To position the stability test chock align the positioning pins on the chock with the positioning holes in the platform ...

Page 20: ...using the device DANGER TO MINIMIZE THE RISK OF ELECTRIC SHOCK Ensure that the circuit breakers are tripped and make sure the voltage is off after its use and before its cleaning Check that the voltage indicated on the nameplate matches the voltage of the power outlet 1 meter CLEARANCE provide a clearance of 1 meter all the way around the device keeping the area free of any objects or people INSTA...

Page 21: ... the circuit upstream from the machine This must comply strictly with all appropriate safety regulations and restrictions Ensure that the circuit breaker rating is in correct correspondence to the HUBER 360 MD the upstream circuit breaker must be rated higher than the machine Place the wall connection box with isolating cover as close to the main electrical supply as possible for a permanent conne...

Page 22: ...rvice center for examination and repair Do not move the device by pulling on its power cord Never use the device if the vents are blocked Keep openings free of dust and other contaminants Do not drop or insert any objects into any of the openings This could damage the machine Do not use the device on a dirt or uneven floor or in a humid or salty environment and do not expose it to bad weather Do n...

Page 23: ...uipment for exercise Users should breathe regularly while exercising Using this equipment with maximum effort is not recommended while the platform is moving The user should stop immediately if experiencing any discomfort during exercise Do not operate the unit in unsuitable environmental conditions see technical specifications When using the articulated stool the user s feet should rest on the wo...

Page 24: ...ible interference it is important that the professional ensure that the patient is not fitted with a personal medical equipment such as a pacemaker or a hearing aid If this is the case determine with certainty whether the equipment in question emits a signal that may interfere with the functioning of the unit The unit must not be used by someone with a medical condition unless accompanied at all t...

Page 25: ...2 6 I M P O R T A N T S A F E T Y I N F O R M A T I O N 3 ELECTROMAGNETIC COMPATIBILTY For more information on electromagnetic compatibility refer to Electromagnetic Compatibility in the appendix ...

Page 26: ...fectant solution to clean the handles and the platform Use a screen wipe impregnated with bactericide and antistatic solution to clean the dashboard Use a vacuum cleaner with a narrow attachment to clean the platform and the inside of the accessory positioning recesses For technical problems please refer to Chapter 5 Troubleshooting IDENTIFICATION NAMEPLATE SERIAL NUMBER VOLTAGE AND FREQUENCY The ...

Page 27: ...evice reaches the end of its useful life it must be brought to an appropriate recycling center or returned to your dealer By doing so you help the environment by contributing to the conservation of natural resources and the protection of human health This symbol means that some specific warnings or precautions associated with this device are not on the label This symbol means carefully read the ac...

Page 28: ...2 9 M A I N T E N A N C E 4 POWER CORD If the power cord of your device is damaged please contact LPG Systems Customer Service for a replacement LPG Systems Customer Service 33 0 4 75 78 69 89 NOTES ...

Page 29: ...y stop button and then restart the machine For the symptoms listed below stop the machine and wait 60 seconds before restarting Error message displayed on the screen Screen not working Excessive weight applied to the platform during exercise Fault on the sensor Once these checks have been completed and if the problem persists please contact LPG Systems Customer Service or the nearest authorized de...

Page 30: ...ong time 750VA Momentary 1800VA Platform Movement Maximum oscillation frequency 1 tr sec Maximum amplitude 10 Force Measurement Handle measurement scale 0 to 85 kg Weight measurement Measurement range 0 to 165 kg User Replaceable Batteries Heart rate monitor 1 pile 3V CR2032 Surrounding environment restrictions Operating temperature 10 C to 30 C Storage temperature 20 C to 70 C Ambient relative hu...

Page 31: ... CONT Device designed for uninterrupted use Huber 360 MD is marked as a medical device under appendix II of the 93 42 EC directive consolidated version including the 2007 47 EC Directive T E C H N I C A L S P E C I F I C A T I O N S ...

Page 32: ...teed against any manufacturing defect Beyond the legal warranty the commercial warranty lasts as long as the shorter of the two following periods one 1 year OR two thousand 2000 hours of use since the billing date During this period we undertake to exchange or repair free of charge and as quickly as possible any part acknowledged by us as being defective without necessarily replacing the entire un...

Page 33: ...d or of a different voltage than that indicated on the unit If a device is sold before the end of the warranty the remainder of the warranty will be transferred to the new owner provided that 1 The original invoice is transferred to the new owner 2 The original seller is informed of the sale Modification fitting accessories or dismantling the unit Any use and or intervention not provided for in th...

Page 34: ...ial loss of any nature whatsoever or for any losses suffered of any kind financial commercial image etc that are the direct or indirect consequence of a malfunction and or non conforming use of the device In any event if LPG Systems is found to be responsible for a device that is sold and or services that are performed the maximum amount of damages and interest for which either or both party may b...

Page 35: ...ers relations including after sales service and warranties Information with an asterisk must be provided in order for this form to be processed According to modified French law 78 17 from January 6 1978 relating to computers digital files and freedoms also known as the Informatique et Libertes law you have a right of access rectify and remove personal data about you by contacting LPG Systems in wr...

Page 36: ... the air Flooring should be made of wood concrete or ceramic tile If the floor is covered with synthetic material relative humidity should be at least 30 Fast transient burst IEC 61000 4 4 2 kV for electrical power lines 1 kV for input output lines 2 kV for electrical power lines 1 kV for input output lines The quality of the electrical power network should be equivalent to that of a typical comme...

Page 37: ...ile radios amateur radios AM and FM radio broadcasting and TV broadcasting cannot be theoretically predicted with accuracy To measure the electromagnetic environment due to fixed RF transmitters consider performing an electromagnetic survey of the site If the field strength measured where the HUBER 360 MD is used exceeds the applicable RF conformity level above watch the HUBER 360 MD to ensure tha...

Page 38: ...AX 33 0 4 75 42 80 85 INTERNATIONAL MARKETING 2753 ROUTE DES DOLINES BP 243 06905 SOPHIA ANTIPOLIS CEDEX FRANCE TEL 33 0 4 92 38 39 00 FAX 33 0 4 92 96 09 65 1786 Ed 10 14 GB LPG Systems 2014 LPG Systems SA au capital de 2 124 950 euros Siren RCS 335 183 836 Romans Any reproduction even in part is strictly prohibited Non binding photos ...

Reviews: