Operation
44
MultiPress S
Operating manual 3.0
Rev: 3.6.2009
6.5.1 Starting the preheating stage
The preheating stage can be switched on automatically when the
MultiPress Sis switched on and/or started manually.
Bringing the press jaws together
In order to reach the target temperature as quickly as possible, the press
jaws should be closed during the preheating state. This is done in the
MultiPress S program-controlled by means of the automatic hydraulic
pump.
›
In the MultiPress S with hand pump:
Pump repeatedly until the manometer shows a pressure of 10 bar
(145 psi).
Starting the preheating stage automatically
›
In the menu
Setup
>
Preheating
, select the entry
On
and press the
ENT
key.
The preheating is started automatically when the MultiPress S is
switched on. Please note that the press profile selected last will be
used. (see table Tab. 2: „Setup menu“ on page 40).
Starting the preheating stage manually
›
Make sure that the desired press profile is displayed in the profile
box.
›
In the main menu, select the entry
Start
.
›
Press the
ENT
key.
"
start
" appears in the menu box.
›
Select the entry
Preheating
and press the
ENT
key.
The display shows the current data of the preheating state.
Fig. 16: Display during the
preheating stage
p r e h e a t
L PKF S e t
2 5 0 ° C mu s t
t emp .
2 2 ° C
u t emp e r a t u r e
2 2 ° C
l
t emp e r a t u r e
Summary of Contents for MultiPress S
Page 2: ......
Page 12: ...For your notes 10 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 15: ...Table of contents MultiPress S Operating manual 3 0 Rev 3 6 2009 13 13 Index 73...
Page 30: ...For your notes 28 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 38: ...For your notes 36 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 58: ...For your notes 56 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 60: ...For your notes 58 MultiPress S Operating manual 3 0 Issued 3 6 2009...
Page 70: ...Technical Data 68 MultiPress S Operating manual 3 0 Rev 3 6 2009...