LPKF ProtoMat 93s Manual
50
9. Check the correct insertion depth of the spindle before setting it into operation.
The distance between the drill tip and the machine plate must be 0.5 mm when
the head is in its lower position.
10.
Caution! The machine plate can be damaged during drilling when this distance
is too small.
At an insufficient distance the device can no longer drill through the
workpiece.
11.At last tighten the screws again (3) and put the connector again on the spindle.
0.5mm
Check the distance when mounting the high-speed spindle
8.2 Serial port SERIAL 1
The serial data channel SERIAL 1 is an RS 232-C standard interface with photo
diode decoupling and is used for communication between the control unit and a
PC. The DCD signal input on the control means that the control unit can be
STOPPED quickly when the signal level changes from low to high. In this way, it is
possible to stop the machine directly from the PC by activating the DTR signal.
The SERIAL 1 transmission speed is programmed with DIL switches 1 and 2.
Switch 1
Switch 2
Baud rate
OFF
OFF
4800 baud
ON
OFF
9600
baud
OFF
ON
19200
baud
ON
ON
-