How-To Document
Updated on:
11/13/2008
By:Christopher Ware
Page 5 of 13
h. Place the spindle control board cover into position.
i. Make sure that the ribbon cable is placed in the slot in the spindle control board cover.
i.
Insert and tighten the two (2) T10 torque screws on the spindle control board cover.
5. If installed, Remove vacuum table
a. Switch on the machine and start boardmaster.
i. When prompted, enter the tool status.
b. Move the machine to the pause position.
c. Remove the white underlay material from the vacuum table.
d. With the T20 torque wrench remove the two (2) T20 torque screws in the vacuum table bed
e. With a large tip flat head screw driver, unscrew the six (6) flat head screws in the vacuum table
bed.
f.
Unhook the two (2) vacuum tubes from the vacuum table base.
i. Allow the vacuum tubes to fold to the back of the machine.