Appendix 1. Troubleshooting
APP1-13
9. Error Message during Execution of Programs
In case that problems occur during execution of XGT Panel including the start of device, diagnosis of device and
environment setting, project download, monitoring of control device, and error messages occur as type of box. At
this time the message indicates the code made by 4 digit number. The front 2 number indicate code of object
and work, the rear 2 number is message number. In case that the present error message is indicated as [0101],
an error message occurs when doing diagnosis about the status of NVRAM. When an error message occurs,
refer to the row’s number and sequence and find the category of reason and measure.
Object
Error code
Occurren
ce
location
Error message
Reason and measure
Type
Address
Device
diagnosis
0x01
0x01
XGT
Panel
NVRAM Data
Access ... FAILED!
Failed to check whether backup
memory is normal or not. If this
symptom is repeated, contact the near
Customer Service Center.
0x02
XGT
Panel
BATTERY STATUS ...
NOT GOOD!
Backup data is not valid. If this
symptom is repeated when turning
power off and on, remove XGT Panel’s
power and exchange the battery.
0x03
XGT
Panel
Write Operation
FAILURE!
The built-in Flash disk has an error.
Contact the near Customer Service
Center.
0x04
XGT
Panel
Read Disk Information
Error!
The built-in Flash disk has an error.
Contact the near Customer Service
Center.
0x05
XGT
Panel
Write Operation
FAILURE!
Check that CF card is empty, and equip
CF card and test again. If same
symptom is repeated, CF card or CF
card slot of XGT Panel may have a
problem.
0x06
XGT
Panel
Read Disk Information
Error!
Check that CF card is empty, and equip
CF card and test again. If same
symptom is repeated, CF card or CF
card slot of XGT Panel may have a
problem.
Device
setting
0x02
0x01
XGT
Panel
Invalid timeout value.
You inputted the wrong time which is
not within backlight setting time range.
Input the effective time.
0x02
XGT
Panel
Not found XGT Panel
configuration file.
There is no setting information data of
XGT Panel. If this symptom is repeated
when turning power off and on, contact
the near Customer Service Center.
0x03
XGT
Panel
Please enter an
integer between 0 and
255.
When setting IP, the values within
0~255 are effective. Input the value
within the above range.
Summary of Contents for iXP2 Series