L7C Series AC Servo Drives Quick Start Guide
Page 25 of 60
L7C Servo Drives Quick Start Guide – 1st Ed. Rev A, 11/29/2021
Digital Input Codes
Parameter
Setting
Code
Function
NC
NO
0x8000 0x0000 Not assigned Input not used
0x8001 0x0001
POT
Prohibit forward
rotation (CCW limit)
0x8002 0x0002
NOT
Prohibit reverse
rotation (CW limit)
0x8003 0x0003
HOME
Origin sensor
0x8004 0x0004
STOP
Stop servo
0x8005 0x0005
PCON
Operate P control
0x8006 0x0006
GAIN2
Switch between Gain1
and Gain2
0x8007 0x0007
P_CL
Forward torque limit
0x8008 0x0008
N_CL
Reverse torque limit
0x800b 0x000b
EMG
Emergency stop
0x800C 0x000C
A_RST
Reset alarm
0x800F 0x000F
SV_ON
Servo on
0x8010 0x0010
START
Start operation
0x8011 0x0011
PAUSE
Pause index
0x8012 0x0012
REGT
Registration input
0x8013 0x0013
HSTART
Start homing
0x8014 0x0014
ISEL0
Selection position 0
0x8015 0x0015
ISEL1
Selection position 1
0x8016 0x0016
ISEL2
Selection position 2
0x8017 0x0017
ISEL3
Selection position 3
0x8018 0x0018
ISEL4
Selection position 4
0x8019 0x0019
ISEL5
Selection position 5
0x801A 0x001A
ABSRQ
Request absolute
position data
0x801b 0x001b
JSTART
Operate jog
0x801C 0x001C
JDIR
Select jog rotation
direction
0x801d 0x001d
PCLR
Clear input pulse
0x801E 0x001E
AOVR
Select velocity override
0x8020 0x0020 SPD1/LVSF1 Multi-step speed 1 /
Vibration control filter 1
0x8021 0x0021 SPD2/LVSF2 Multi-step speed 2 /
Vibration control filter 2
0x8022 0x0022
SPD3
Multi-step speed 3
0x8023 0x0023
MODE
Switch operation mode
0x8024 0x0024
EGEAR1
Electric gear 1
0x8025 0x0025
EGEAR2
Electric gear 2
0x8026 0x0026 ABS_RESET Absolute position reset