![background image](http://html1.mh-extra.com/html/ls-industrial-systems/xbc-dn10e/xbc-dn10e_user-manual_1943831155.webp)
Chapter 6 Instruction Details
XBC E-Type Main Unit
6-38
Ver. 1
3) Program Example
(1) If Input Condition of P00020 is On, P00060 Output will be On, and at the same time P00061 Output will be
Off. While D00020.3 changes 0
1 for 1 scan, P00062 Output will be On, and while D00020.3 changes
1
0 for 1 scan, P00063 Output will be On.
[ Ladder Program]
P00020
( )
P00060
0
P00020
( )
P00061
D00020.3
( )
P00062
D00020.3
( )
P00063
2
4
6
P
N
b0
b15
b3
1/0
D20
[Mnemonic Program]
[Time Chart]
1Scan
OFF
P00020
P00060
P00061
P00062
P00063
D00020.3
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
1Scan
Step
Mnemonic Operand
0
LOAD
P00020
1
OUT
P00060
2
LOAD NOT P00020
3
OUT
P00061
4
LOADP
D00020.3
5
OUT
P00062
6
LOADN
D00020.3
7
OUT
P00063
Summary of Contents for XBC-DN10E