Chapter 6 Instruction and Flag List
XBC E-Type Main Unit
6-215
Ver. 1
2) DMIN (Double Minimum)
(1) Searches from double word data S up to N range for the minimum value to save in D.
(2) Comparison in size will be performed by signed operation.
(3) If operation result is Zero, Zero Flag will be set.
(4) If N=0, the instruction will not be executed.
3) Program Example
(1) When D01000=1111, D01001=3333, D01002=2222, D01200=h0003, if Input Signal P00000 is changed
from Off to On status, it saves D01100=1111.
P00000
MINP D01000 D01100 D01200
Searching range
( n )
Head No. of object to search
-365412
Minimum value
D
S
S + 2
S + 4
S + 6
S + (2n-8)
S + (2n-6)
S + (2n-4)
S + (2n-2)
-12345
25894
256
588479
145
26594823
-258
-365412