![background image](http://html1.mh-extra.com/html/ls-industrial-systems/xbc-dn10e/xbc-dn10e_user-manual_1943831337.webp)
Chapter 6 Instruction and Flag List
XBC E-Type Main Unit
6-220
Ver. 1
6.32.15 MUX, MUXP, DMUX, DMUXP
Instruction
Area Available
Step
Flag
P M K
F
L
T
C
S
Z D.x R.x
Con
st
U
N
D
R
Error
(F110)
Zero
(F111)
Carry
(F112)
MUX(P)
DMUX(P)
S1 O O O O O O O
-
O
-
-
-
O O O O
4~7
O
-
-
S2 O O O O O O O
-
O
-
-
-
O O O O
D
O O O
-
O O O
-
O
-
-
-
O O O O
N
O O O
-
O O O
-
O
-
-
O O O O O
Operand
Description
Data Type
S1
Position to select (0~N-1)
WORD/DWORD
S2
Head position of data to select
WORD/DWORD
D
Area where selected value will be saved
WORD/DWORD
N
Range of data to select
WORD
[Flag Setting]
Flag
Description
Device Number
Error
If N exceeds applicable device’s range
Position to select data exceeds searching range.
F110
1) MUX
(1) Transfers data applicable to S1
st
among N word data from S2 to D.
2) DMUX
(1) Transfers data applicable to No.S1 among N double word data from S2 to D.
3) Program Example
(1) When D01100=h1111, D01101=h3333, D01102=h2222, D01000=h0001, D01300=h0003, if Input Signal
P00000 is changed from Off to On, it saves D01200=h3333.
P00000
MUXP D01000 D01100 D01200 D01300
(D)MUX
means (D)MUX
P S1
(D)MUXP
S1
D
N
S2
D
N
S2
4
S2
S2+1
S2+2
S2+(N-2)
S2+(N-1)
70
35
5
357
53
10
20
77
357
D
S1
Position to select
S2+3