Chapter 6 Instruction Details
XBC E-Type Main Unit
6-252
Ver. 1
(3) The specified number of characters N, specified string S’s range, and specified device D’s range to save
Binary data in will be automatically set.
(4) Even if the device range where ASCII data to convert is saved and the device range where converted Binary
data will be saved are duplicated, its process will be normal.
(5) If specified number of characters N is not the multiple of 4, “0” will be saved automatically after specified
number of characters of the last device number in the device range to save converted Binary data.
(6) If specified number of characters N is “0,” no conversion will be executed.
2) Program Example
P00000
HEX P1000 P1100 P1200