![background image](http://html1.mh-extra.com/html/ls-industrial-systems/xbc-dn10e/xbc-dn10e_user-manual_1943831386.webp)
Chapter 6 Instruction Details
XBC E-Type Main Unit
6-269
Ver. 1
6.35.12 EXP, EXPP
Instruction
Area Available
Step
Flag
P M K
F
L
T
C
S
Z D.x R.x
Con
st
U
N
D
R
Error
(F110)
Zero
(F111)
Carry
(F112)
EXP(P)
S
O O O
-
O O O
-
-
-
-
O O O O O
2~4
O
-
-
D
O O O
-
O
-
-
-
-
-
-
-
O O O O
Operand
Description
Data Size
S
Input value to perform exponential operation
LREAL
D
Device number to save operation result in
LREAL
1) EXP (Exponential operation)
(1) Performs Exponential operation of data in specified area S to save in D. Data type of S and D is of double
real.
(2) When S is over 2.0, operation result is
7.3890...(
2
e
)
2) Program Example
P00001
LOG M0000 M0004
Performs exponential operation of data in M0000, M0001 and saves them in M0004, M0005.
EXP
EXPP
S
D
EXPP
EXP
S
D