![background image](http://html1.mh-extra.com/html/ls-industrial-systems/xbc-dn10e/xbc-dn10e_user-manual_1943831482.webp)
Chapter 8 Option Boards and Memory Module
XBC E-Type Main Unit
8-19
Ver. 1
2. No. 9 slot device area
a. Action command
Type
Device area per each channel
Ref.
CH0
CH1
CH2
CH3
Enable counter
U9.0.0
U9.8.0
U9.16.0
U9.24.0
BIT
Enable internal preset
U9.0.1
U9.8.1
U9.16.1
U9.24.1
BIT
Count inc./dec. flag
U9.0.3
U9.8.3
U9.16.3
U9.24.3
BIT
Latch counter enable
U9.0.6
U9.8.6
U9.16.6
U9.24.6
BIT
Pulse input mode
U9.5
U9.13
U9.21
U9.29
INT
Internal preset setting value
U9.6
U9.14
U9.22
U9.30
DINT
b. Monitor area
Type
Device area per each channel
Ref.
CH0
CH1
CH2
CH3
Carry flag
U9.1.0
U9.9.0
U9.17.0
U9.25.0
BIT
Borrow flag
U9.1.1
U9.9.1
U9.17.1
U9.25.1
BIT
Current counter value
U9.2
U9.10
U9.18
U9.26
DINT
Error code
U9.4
U9.12
U9.20
U9.28
INT
3. No. 10 slot device area
a. Action command
Type
Device area per each channel
Ref.
CH0
CH1
CH2
CH3
Enable counter
UA.0.0
UA.8.0
UA.16.0
UA.24.0
BIT
Enable internal preset
UA.0.1
UA.8.1
UA.16.1
UA.24.1
BIT
Count inc./dec. flag
UA.0.3
UA.8.3
U9.16.3
UA.24.3
BIT
Latch counter enable
UA.0.6
UA.8.6
UA.16.6
UA.24.6
BIT
Pulse input mode
UA.5
UA.13
UA.21
UA.29
INT
Internal preset setting value
UA.6
UA.14
UA.22
UA.30
DINT
b. Monitor area
Type
Device area per each channel
Ref.
CH0
CH1
CH2
CH3
Carry flag
UA.1.0
UA.9.0
UA.17.0
UA.25.0
BIT
Borrow flag
UA.1.1
UA.9.1
UA.17.1
UA.25.1
BIT
Current counter value
UA.2
UA.10
UA.18
UA.26
DINT
Error code
UA.4
UA.12
UA.20
UA.28
INT