6. Communication Protocol
6-10
6.3
L7 Servo Drive Communication Address
Table
6.3.1
Operation Status Parameter Communication
Address Table
Communication
Address
Parameter Name
Parameter
Number
Material Type
(Decimal
Number)
Operation Status Display Parameter
0
Current operation status
St - 00
INT16
BIT0: Alarm
BIT1: Servo on
BIT2: Warning
BIT3: CCW limit
BIT4: CW limit
BIT5: Zero speed
BIT6: In speed
BIT7: In position
BIT8: Power ready
BIT9: Analog command active
BIT10 - BIT13: Control mode
(0: Trq, 1: Spd, 2: Pos, 3: Spd/Pos,
4: Trq/Spd, 5: Trq/Pos)
2
Current operation speed
St - 01
INT16
4
Current command speed
St - 02
INT16
6
Tracking position pulse - L
St - 03
INT32
8
Tracking position pulse - H
10
Position command pulse - L
St - 04
INT32
12
Position command pulse - H
14
Remaining position pulse -
L
St - 05
INT32
16
Remaining position pulse -
H
18
Input pulse frequency
– L
St - 06
INT32
20
Input pulse frequency - H
22
Current operation torque
St - 07
INT16
24
Current command torque
St - 08
INT16
26
Accumulated overload rate
St - 09
INT16
28
Instantaneous maximum
load factor
St - 10
INT16
30
Torque limit value
St - 11
INT16
32
DC Link Voltage
St - 12
UINT16
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......