4. Parameters
4-9
(6)
32-bit Signed Integer Data Display
①
Minimum (-2147483648)
Display upper two digits
Display middle four digits
Display lower four digits
②
Maximum (2147483647)
Display upper two digits
Display middle four digits
Display lower four digits
E.g.) [St-16]: Displayed as Upper = 0, Middle = 0012, and
Lower = 2071
Order
Loader Displays
Keys to Use
What to Do
1
Displays the speed control mode with
main power and control power
permitted.
2
Press [MODE] to move to [St-00].
3
Press [UP] or [DOWN] to move to [St-
16].
4
Press [SET] to display lower digit data.
5
Each time you press [/LEFT] or
[/RIGHT]
lower, middle, and upper data is
displayed.
6
Each time you press [/LEFT] or
[/RIGHT]
lower, middle, and upper data is
displayed.
7
Press and hold [MODE] for
approximately one second to return to
[St-16].
NOTE 1)
“ ” indicates flickering.