4. Parameters
4-23
(3)
Output Signal Logic Definition
Output signal logic definition: [P2-10]
The logic of output signals as shipped from the factory is as follows.
Signal Name
Input
Signal
(Initial
Name)
CN1 Pin Default Allocation Number
Contact B
Output
Signal
Logic
Definition
Default
Setting
Parameter Allocation
45
44
43
40 /41
38 /39
Alarm
[P2-10].Set Digit 1
ALARM
0
[P2-10]
0x10110
Servo Ready
[P2-10]. Set Digit 2
READY
1
0
Zero speed achieved
[P2-10].Digit 3
ZSPD
1
0
Brake
[P2-10].Digit 4
BRAKE
0
Position reached
[P2-10].Digit 5
INPOS
1
0
NOTE 1)
For the purpose of the input signal logic definition, Contact A is 1 and Contact B is 0
Output signal logic definition number
Output signal logic definitions
DO1(Contact A/Contact B)
DO2(Contact A/Contact B)
DO3(Contact A/Contact B)
DO4(Contact A/Contact B)
DO5(Contact A/Contact B)
Summary of Contents for L7 A001