4. Parameters
4-41
Parameter
Unit
Initial
Details
Code
Name
Minimum
Maximum
P3-13
Program JOG operation
speed 1
[RPM]
0
Sets operation speed/operation time for programs 1
to 4 during program JOG operation [Cn-01].
A test run repeats from step 1 to step 4.
Sets operation speed ([P3-13]-[P3-16]) and
operation time ([P3-17]-[P3-20]) for each step.
E.g.) Step 1 operation
Program jog speed 1
-6000
6000
P3-14
Program JOG operation
speed 2
[RPM]
3000
Program jog speed 2
-6000
6000
P3-15
Program JOG operation
speed 3
[RPM]
0
Program jog speed 3
-6000
6000
P3-16
Program JOG operation
speed 4
[RPM]
-3000
Program jog speed 4
-6000
6000
P3-17
Program JOG operation
time 1
[ms]
500
Program jog time 1
0
65535
P3-18
Program JOG operation
time 2
[ms]
5000
Program jog time 2
0
65535
P3-19
Program JOG operation
time 3
[ms]
500
Program jog time 3
0
65535
P3-20
Program JOG operation
time 4
[ms]
5000
Program jog time 4
0
65535
Summary of Contents for L7 A001
Page 1: ...VER 1 5...
Page 2: ......
Page 32: ...1 Product Components and Signals 1 20...
Page 38: ...2 Installation 2 6...
Page 54: ......
Page 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Page 210: ...8 Maintenance and Inspection 8 14...
Page 211: ...9 Appendix 9 1 9 Appendix...
Page 218: ...9 Appendix 9 8...
Page 221: ......
Page 222: ......