LSI LASTEM E-Log – User’s manual
43
Acquisition of instantaneous values sampled from sensors with LSI
LASTEM CISS protocol
X
X
Management of system commands (start/stop survey, memory
format, instrument reset, etc.)
X
X
TTY
Transmission of instantaneous values of the measures (in polling
mode or spontaneous transmission)
X
Transmission of instrument registry information
X
Transmission and reset of diagnostic information updated in real time
X
Setting of system date/time
X
Modbus RTU
Master/Slave
Request/Transmission of instantaneous values of the measures (fixed
point or floating point)
X
Transmission and setting of digital outputs (actuators)
X
Transmission of instrument registry information
X
Transmission and reset of diagnostic information updated in real time
X
Transmission and setting of system date/time
X
Aeroqual
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Gill
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Hydrolab
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Climatronics
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Biral
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Komoline
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
Boschung
Acquisition of sampled instantaneous values and transmission from
connected instrument
X
ZigBee
All commands provided in owner LSI LASTEM CISS protocol
X
PSTN/GSM
Modem
Available in trasparent mode with any protocol
X
X
GPRS Modem
Support to communication on TCP socket (encapsulation of the only
owner LSI LASTEM CISS protocol), or with FTP protocol
(transmission of elaborated data in binary format)
X
RS232/Ethernet
Converter
Available in trasparent mode with any protocol or in
Modem
emulation
mode
X
X
(**)
(*) Function obtained by programmation of appropriate calculated measures.
(**) Does not support the
Modem emulation
mode.
5.6.4.
Communication devices
E-Log has different communication devices that can be used for the connection to the data
collection systems:
DEC301 radio communicator: it operates at 434 MHz frequency, has 300 m as the crow flies
capacity, connection rate 9600 bps; it can be connected to PC together with an other
DEC301 communicator; it can be connected both serial port 1 and serial port 2 of E-Log;
reference manual: INSTUM_00067.
ZigBee radio: it operates at 2.4 GHz frequency, it has about 100 m as the crow flies
capacity; connection rate up to 115 kbps; it allows the LSI LASTEM sensors reception
Summary of Contents for E-Log
Page 1: ...Cod INSTUM_00351_en E Log User s manual Updated on 09 18 2017...
Page 15: ...LSI LASTEM E Log User s manual 15...
Page 60: ...LSI LASTEM E Log User s manual 60 6 6 Mask of terminal board...
Page 61: ...LSI LASTEM E Log User s manual 61 6 7 Connection cables...
Page 62: ...LSI LASTEM E Log User s manual 62 6 8 Declaration of Conformity...