All displayed parameters identify the network. In case of transmission disturbance it is possible to
modify the frequency channel by modifying the
CHANNEL
parameter (values allowed from 11 to 26).
13.
The
RADIO
tab specifies the radio operating parameters.
In particular:
➢
PARENT POLLING RATE
: is the data transmission rate. In battery-powered sensors this para-
meter is set by default to 3 minutes.
The sensor’s radio is switched on only for the time it
takes to transmit the data, then it turns off and the sensor switches to low power mode. In
this mode the sensor is not accessible from Sphensor Gateway.
If the sensor is externally powered by USB, it is recommended to set this parameter to
00:00:00.
➢
TX POWER
: specifies the power of the radio signal. It is advisable to leave this parameter
unchanged.
14.
The
MEASURES
tab displays the list of measurements generated by the sensor.
For each measure is displayed:
-
Name
: is the name of the measure.
-
In Use
: specifies whether or not the measurement is acquired by the sensor (Yes = acquired;
No = not acquired).
-
Rate
: is the acquisition rate of the measure.