Smoothing
: specifies if a sliding average has been set (if set: number of values used to com-
pute the running average).
-
User Calibration
,
Forced range
,
Validity range
,
Remap
: these parameters are currently reser-
ved for use by LSI LASTEM technicians.
To access the window with the measurement parameters,
double-click
on the measurement.
The displayed parameters are the following:
➢
SAMPLING RATE
: is the update rate of the measure.
➢
SMOOTHING
: is the number of samples constituting the measure. If it is 0 or 1. the transmit-
ted value corresponds to the acquired value. If greater than 1. the transmitted value corre-
sponds to the average of the latest
SMOOTHING
acquisitions. For example, if
SAMPLING
RATE
is equal to 5 and
SMOOTHING
is equal to 12, the sensor will transmit the value, every
5 seconds, corresponding to the (sliding) average of the last minute.
15.
Press [SAVE] to save the configuration. The sensor configuration dialog updates with the new confi-
guration.
16.
Select the new configuration and choose
Send
to send it to the sensor. This will be sent as soon as
the sensor communicates with Sphensor Gateway (see PARENT POLLING RATE sensor parameter).
17.
Wait for the sensor reboot light to verify the success of the operation, then turn off the sensor and
proceed with the next one.
3.3
Repeater configuration
The configuration of the repeaters is done in the same way as the sensors:
➢
Device start-up and wait for the recognition by
Sphensor Manager
.
➢
Double-click
the device and configuration reading.
➢
Cloning of the configuration.
➢
Changes in radio network parameters, the only ones that can be modified.
➢
Configuration saving and transmission to the device.
➢
Device shut down.