Parameter Setting Mode
The following table lists the functions groups under Parameter mode.
Function Group Name Keypad Display Description
Drive
DRV
Configures basic operation parameters. These
include jog operation, motor capacity evaluation, and
torque boost.
Basic
BAS
Configures basic operation parameters. These
parameters include motor parameters and multi-step
frequency parameters.
Advanced
ADV
Configures acceleration or deceleration patterns,
frequency limits, energy saving features, and,
regeneration prevention features.
Control
CON
Configures the features related to speed search and
KEB (kinetic energy buffering).
Input Terminal
IN
Configures input terminal
–related features, including
digital multi
–functional inputs and analog inputs.
Output Terminal
OUT
Configures output terminal
–related features,
including digital multi
–functional outputs and analog
outputs.
Communication
COM
Configures the USB-related features and
communication features for the RS-485, Modbus-
RTU, LS Bus, Metasys N2, and BACnet. Optional
communication module related features may be
configured as well, if one is installed.
PID process
PID
Configures the PID control-related features.
EPID process
EPI
Configures the external PID control-related features.
Application 1
AP1
Configures the Sleep Boost, SoftFill, and Multiple
motor control (MMC) features related to the PID
control.
Application 2
AP2
Configures the HVAC features by setting the features
such as load tuning, pump cleaning, and pay back
counter.
Application 3
AP3
Configures the time event-related features.
Protection
PRT
Configures motor and inverter protection features.
Motor 2 (Secondary
motor)
M2
Configures the secondary motor-related features.
Summary of Contents for H100
Page 14: ......
Page 18: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 27: ...Preparing the Installation 13 ...
Page 47: ...33 Installing the Inverter ...
Page 48: ...Installing the Inverter 34 Input and Output Control Terminal Block Wiring Diagram ...
Page 61: ...47 Installing the Inverter ...
Page 71: ...Learning to Perform Basic Operations 57 ...
Page 88: ...Learning to Perform Basic Operations 74 ...
Page 103: ...89 Learning Basic Features Code Description V1 Quantizing ...
Page 129: ...115 Learning Basic Features ...
Page 140: ...Learning Basic Features 126 ...
Page 148: ...Learning Basic Features 134 ...
Page 171: ...157 Learning Advanced Features Deceleration dwell operation ...
Page 183: ...169 Learning Advanced Features ...
Page 184: ...Learning Advanced Features 170 PID Command Block ...
Page 185: ...171 Learning Advanced Features PID Feedback Block ...
Page 186: ...Learning Advanced Features 172 PID Output Block ...
Page 187: ...173 Learning Advanced Features PID Output Mode Block ...
Page 197: ...183 Learning Advanced Features ...
Page 201: ...187 Learning Advanced Features Code Description 100 EPID1 Control block ...
Page 202: ...Learning Advanced Features 188 EPID2 Control block ...
Page 237: ...223 Learning Advanced Features Time Period Schedule AP3 38 Except3 Day 01 01 ...
Page 244: ...Learning Advanced Features 230 ...
Page 259: ...245 Learning Advanced Features Code Description Code Description Volt ...
Page 362: ...Learning Protection Features 348 ...
Page 415: ...401 RS 485 Communication Features Item Standards Parity check None ...
Page 524: ...Table of Functions 510 ...
Page 533: ...Table of Functions 519 ...
Page 547: ...533 Troubleshooting ...
Page 585: ...Technical Specification 571 ...
Page 594: ...580 ...
Page 595: ...581 ...
Page 596: ...582 ...