Troubleshooting
LCD Display
Description
output terminals or relay (OUT-31–35 or OUT-36) to ‗35
(FanExChange)‘ to receive the fan replacement warning output
signals.
Low Battery
Displayed when the RTC battery voltage drops to or below 2 V. To
receive a warning output signal, set PRT-90 (Low Battery) to ‗Yes‘.
Broken Belt
Displayed when PRT-91 is set to warning and the inverter becomes
on the condition of broken belt.
Load Tune
Displayed when the values of ‗AP2-03 and AP2-04‘ are more than
the values of ‗AP2-09 and AP2-10‘ and the function of load tunning
is not normal.
PareWrite Fail
Displayed when the function of smart copier is not normal.
Rs Tune Err
Displayed when the function of Rs tunning is not normal . For
example, auto tunning is performed without wiring the motor.
Lsig Tune Err
Displayed when the function of Lsigma tunning is not normal . For
example, auto tunning is performed without wiring the motor.
9.2 Troubleshooting Fault Trips
When a fault trip or warning occurs due to a protection function, refer to the following table
for possible causes and remedies.
Type
Cause
Remedy
Over Load
The load is greater than the motor‘s
rated capacity.
Ensure that the motor and inverter
have appropriate capacity ratings.
The set value for the overload trip level
(PRT-21) is too low.
Increase the set value for the
overload trip level.
Under Load
There is a motor-load connection
problem.
Replace the motor and inverter with
models with lower capacity.
The set value for underload level (PRT-
24) is less than the system‘s minimum
load.
Reduce the set value for the
underload level.
Over
Current1
Acc/Dec time is too short, compared to
load inertia (GD
2
).
Increase Acc/Dec time.
The inverter load is greater than the
rated capacity.
Replace the inverter with a model
that has increased capacity.
Summary of Contents for LSLV0055H100-4COFN
Page 14: ......
Page 18: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Page 27: ...Preparing the Installation 13 ...
Page 47: ...33 Installing the Inverter ...
Page 48: ...Installing the Inverter 34 Input and Output Control Terminal Block Wiring Diagram ...
Page 61: ...47 Installing the Inverter ...
Page 71: ...Learning to Perform Basic Operations 57 ...
Page 88: ...Learning to Perform Basic Operations 74 ...
Page 103: ...89 Learning Basic Features Code Description V1 Quantizing ...
Page 129: ...115 Learning Basic Features ...
Page 140: ...Learning Basic Features 126 ...
Page 148: ...Learning Basic Features 134 ...
Page 171: ...157 Learning Advanced Features Deceleration dwell operation ...
Page 183: ...169 Learning Advanced Features ...
Page 184: ...Learning Advanced Features 170 PID Command Block ...
Page 185: ...171 Learning Advanced Features PID Feedback Block ...
Page 186: ...Learning Advanced Features 172 PID Output Block ...
Page 187: ...173 Learning Advanced Features PID Output Mode Block ...
Page 197: ...183 Learning Advanced Features ...
Page 201: ...187 Learning Advanced Features Code Description 100 EPID1 Control block ...
Page 202: ...Learning Advanced Features 188 EPID2 Control block ...
Page 237: ...223 Learning Advanced Features Time Period Schedule AP3 38 Except3 Day 01 01 ...
Page 244: ...Learning Advanced Features 230 ...
Page 259: ...245 Learning Advanced Features Code Description Code Description Volt ...
Page 362: ...Learning Protection Features 348 ...
Page 415: ...401 RS 485 Communication Features Item Standards Parity check None ...
Page 524: ...Table of Functions 510 ...
Page 533: ...Table of Functions 519 ...
Page 547: ...533 Troubleshooting ...
Page 585: ...Technical Specification 571 ...
Page 594: ...580 ...
Page 595: ...581 ...
Page 596: ...582 ...