background image

10 

 

Warranty  

Product is covered  by 2 years Limited Warranty (from the date of purchase). Limited Warranty covers 
any defects in material or manufacturing defects under normal use and maintenance. 

We reserve the 

right not to accept the claim in the case of mechanical damage that could be related to the defect of 
the product or if the product was disassembled by unauthorized service.

 

This  limited  warranty  also  does  not  cover  any  problem  that  is  caused  by  conditions,  malfunctions  or 
damage not resulting from defects in material or workmanship. 
 
During  warranty  period,  we  will  repair  or  replace  defective  product  or  defective  parts.  To  obtain 
warranty service, you must first contact us to determine the problem and the most appropriate solution 
for you. 
 

Safety notice 

This  device  should  be  installed  by  specialized  garage  or  service.  Inappropriate  mounting  or  electrical 
connection  may  result  in  damaging  this  or  any  other  electrical  devices  in  the  motorcycle.  Improper 
installation of fuel hoses can cause the fuel to leak and a fire resulting in damage the motorcycle and the 
owner’s health. 
Device is not approved for use at public roads. You use it at your own risk and responsibility.  

 

Troubleshooting 

If you obey all the instructions, this fuel gauge should work properly without problems. In case of any 
problems, feel free to contact us. 
 
-

 

If the gauge doesn’t show anything on the display, check out all the connections of the device.  

-

 

If the gauge shows nonsense and is calibrated correctly, try checking, if you filled up the fuel hoses 
like explained on page three. 

-

 

Wrong data display is often caused by dirty fuel strainer in the fuel tank, dirty fuel filter if the gauge is 
connected after it or just marginally opened fuel cock. In case of problems, try to check/replace these 
parts.  This  fault  is  often  represented  by  the  amount  of  fuel  dependant  on  engine  revs.  Pressure 
sensor fail is very improbable – problems are usually caused by something else.  

 
If nothing helps, contact us. 
 

 

 

 

Summary of Contents for FGP-DIG-SEG

Page 1: ...FuelGaugePro Bar Graph Display Panel FGP DIG SEG INSTALLATION MANUAL ...

Page 2: ...panel 3 Settings diagram 4 Calibration 5 Calibration type choice 5 Simple low high fuel level calibration 6 Calibration with fuel tank shape compensation 7 How the gauge displays the calibrated data 8 Bottom segment flashing on empty tank 9 Factory reset 9 Warranty 10 Safety notice 10 Troubleshooting 10 Recycling 11 For more information ...

Page 3: ...visibility on the direct sunlight and not blinding at night the display panel have automatic brightness regulation After installation the whole system needs to be calibrated except bike specific kits where the system is factory calibrated Calibration data are stored in display panel Technical specification Supply voltage 12V DC supplied by FuelGaugePro Float free Fuel Level Sensor Energy consumpti...

Page 4: ... Clean the surface with alcohol for the best adhesion of the 3M adhesive tape b Stick the Display Panel on desired place using included 3M adhesive tape 2 Connect the FuelGaugePro Bar Graph Display Panel together with the FuelGaugePro Sensor using original connector ...

Page 5: ...4 Settings diagram Display Panel is equipped with non contact magnetic switch Whole settings and calibration process are performed by proximity the magnet near the place shown on picture ...

Page 6: ...ation to hold the petcock opened 1 Decide what type of calibration you will need a Low high fuel level calibration FuelGaugePro calibrated using low high level calibration measures well enough with most motorcycle fuel tanks The gauge shows the height of the fuel Not the real amount No need to drain the tank Just mount the gauge ride the fuel out and when you switch to reserve set the minimum Go o...

Page 7: ...e magnet out Now the low level is set b High level set Fill the tank to the amount you want to gauge show as a maximum Make sure the petcock is opened and bike stands straight Hold the magnet in active area of Display Panel for 3 5 seconds You should see the animation When it ends take the magnet out The upper segment is now on Proximity the magnet to the active area shortly 0 5 2s and take it out...

Page 8: ...until you see the animation and take the magnet out Now you will see two flashing segments top and bottom o Now the device is prepared for storing first value 0 o We suggest to fill 0 2 0 5l to the empty tank to make sure all fuel hoses are filled up Confirm 0 by proximity the magnet to the active area shortly 0 5 2s and take it out After animation you should see the 1 st bottom flashing segment o...

Page 9: ...8 How the gauge displays calibrated data Used for both types of calibration simple low high fuel level calibration calibration with fuel tank shape compensation ...

Page 10: ...il you see the animation all segments flash few times and take the magnet out Now the setting is toggled Factory reset Using this function resets all settings and calibration data stored in Display Panel to the factory defaults Hold the included magnet in active area of Display Panel as you see on picture on page 2 for 3 5 seconds You should see the animation When it ends take the magnet out The u...

Page 11: ...ult in damaging this or any other electrical devices in the motorcycle Improper installation of fuel hoses can cause the fuel to leak and a fire resulting in damage the motorcycle and the owner s health Device is not approved for use at public roads You use it at your own risk and responsibility Troubleshooting If you obey all the instructions this fuel gauge should work properly without problems ...

Page 12: ...hould be given to places specified for retrieving electrical garbage Package should be thrown into a specific container for recycled garbage Device meets RoHS Directive www lskelectronics com info lskelectronics com Product website ...

Reviews: