background image

 

DX Loudspeaker Controller User Manual 

 

 

 

 

 
 

 
 
 

DX-360/480 

 

 

 

DX SERIES USER MANUAL 

 

LSS Advanced Speakers Systems 

Via On.Longo 53, 

Polistena (RC)  ITALY 

Tel. (+39) 0966 932199 

Fax (+39) 0966 933007

www.lss.it

info@lss.it

89024 

Summary of Contents for DX-360

Page 1: ...X Loudspeaker Controller User Manual 1 DX 360 480 DX SERIES USER MANUAL LSS Advanced Speakers Systems Via On Longo 53 Polistena RC ITALY Tel 39 0966 932199 Fax 39 0966 933007 www lss it info lss it 89024 ...

Page 2: ...RCES This Product should be situated away from heat sources such as radiators stoves or other products including amplifiers that produces heat 9 DO NOT DEFEAT THE SAFETY PURPOSE OF THE POLARIZED OR GROUNDING TYPE PLUG A Polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prongs are provided for you...

Page 3: ...S BEEN SPILLED OR OBJECTS HAVE FALLEN INTO THE APPARATUS THE APPARATUS HAS BEEN EXPOSED TO RAIN OR MOISTURE DOES NOT OPERATE NORMALLY OR HAS BEEN FROPPED 15 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE 16 APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS SUCH AS VASES SHALL BE PLACED ON THE APPARATUS ...

Page 4: ...0 Rear Panel Functions 9 5 0 Powering Up the Device 9 6 0 Operating the Device 10 6 1 Input Output menus 10 6 2 System Menus 13 7 0 QuickReference 17 8 0 PC Control Software 18 9 0 Specifications 19 10 0 Warranty 21 LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39 0966 932199 fax 39 0966 933007 e mail info lss it ...

Page 5: ...s and full function limiters Precise frequency control is achieved with its 1 Hz resolution Inputs and outputs can be routed in multiple configurations to meet any requirement The DX series can be controlled or configured in real time on the front panel or with the intuitive PC GUI accessed via the USB or RS485 Software upgrade for CPU and DSP via PC keeps the device current with newly developed a...

Page 6: ...unction Limiters on Output Channels One Touch easy access setup button Backlit 4 Line x 32 Character LCD Display Full 5 segment LEDs on every Input and Output Storage up to 30 Program Setups USB and RS 485 interfaces for PC Control and Configuration Pink noise and single frequency generator Original Neutrik XLR connectors Security Lock LSS Advanced Speakers Systems via On Longo 53 89024 Polistena ...

Page 7: ...same parameters across multiple channels Multiple Inputs except Channel 1 can be linked together and multiple outputs can be linked together Inputs and Outputs are linked separately 3 Peak Level LED Indicates the current peak level of the Signal Signal 12dB 6dB 3dB Over Limit The Input Over LED references to the device s maximum headroom The Output Limit LED references to the threshold of the limi...

Page 8: ...se large incremental data modifications according to the speed dialed To confirm the setting press the wheel one time 6 LCD 4 line x 32 letters for showing all the necessary information to control the unit 7 Cursor control 4 ways Cursor control LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39 0966 932199 fax 39 0966 933007 e mail info lss it ...

Page 9: ... pin 3 as 5 0 Powering Up the Device After powering up the unit the following initialization screen is displayed on the LCD The initialization process takes about 8 seconds and during that period the unit boots and displays the device model and firmware version After the initialization process is finished the DX displays its main screen The screen shows the current program number and program name ...

Page 10: ...n the Mute key for 1 second then the Channel Edit menu can be used and the green LEDs above the Mute button are lit One Touch easy access setup button DX series have 8 One Touch setup button let user can easily direct control for Signal EQ X over Limiter Channel Name for each input output and System and Exit button Signal Gain POL Delay Signal parameters LEVEL Gain 40 00dB to 12 00dB in 0 1dB step...

Page 11: ...rossover point high pass Types can be Butterworth Linkritz Riley or Bessel FRQH Filter cut off Frequency of low frequency crossover point high pass Ranges from 20 to 20 000Hz in either 1Hz steps or 1 36 octave steps The frequency steps can be selected in the SLPH Filter Slope of low frequency crossover point high pass Ranges from 12 to 48dB octave If the selected Filter Type is Linkritz Riley the ...

Page 12: ...OUT_1 XXXXXX MENU Limiter THRESH 20 0dB ATTACK 10ms RELEASE 2X 20ms Channel Input Mixer 1 2 3 4 Input channel source for the current output channel Can be used to mix the input source or disable it Off If more than one input sources are enabled they will be added together as the source for the current output channel OUT 1 MENU Source InA ON InB ON InC OFF InD OFF Name Channel Name Name Channel nam...

Page 13: ...can be recalled using this menu Load a Xover use the rotary thumb wheel to select and press to confirm selection User Mode Factory Mode Load a Xover User Mode 1 2 3 PROG Program Number to be recalled Store a Xover Program store use the rotary thumb wheel to select and press to confirm selection The DX has a built in non volatile memory that can store up to 30 different program setups A program can...

Page 14: ...ssword The password of the DX is 6 characters in length SYSTEM SETUP MENU Password 0 BackLight Set SYSTEM SETUP MENU Time Light on 20 s The LCD display can set always on or switch off after 20 Second Delay ID SYSTEM SETUP MENU Delay DELAY UNIT ms cm ft Set the Delay unit in ms or cm or ft LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39 0966 932199 fax 39 0966 933007 e...

Page 15: ...ormal Pink Noise Tones XXXX Hz Normal Normal mode Pink Noise Pink Noise Generate mode Tones Tones mode can select any frequency from 20Hz to 20kHz NAME Program Name allows a maximum length of 15 characters SYSTEM Recall P 1 XXXXXXXXXXXX SYSTEM Store P 1 SYSTEM Store NAM XXXXXXXXXXXX LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39 0966 932199 fax 39 0966 933007 e mail ...

Page 16: ...must enter the correct password PASSWORD Under the System Menu The password of the DX is 6 characters in length The user can change it via the PC application software The factory default of a new unit does not require a password Password SYSTEM SETUP MENU Password 0 LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39 0966 932199 fax 39 0966 933007 e mail info lss it ...

Page 17: ...r FTRH Butterworth Linkwitz Riley Bessel Crossover Low XOver FRQH 20 20 000 1 Hz Crossover Low XOver SLPH 12 18 24 48 octave Crossover High XOver FTRL Off Butterworth Linkwitz Riley Bessel Crossover High XOver FRQL 20 20 000 1 Hz Crossover High XOver SLPL 12 18 24 48 octave Out Limiter Thresh Limit THRESH 20 20 0 1 dBu Out Attack Time Limit ATTACK 0 3 100ms 1 ms Out Release Time Limit RELEASE 2 4 ...

Page 18: ...ftware makes it much easier to control and monitor the device allowing the user to get the whole picture on one screen Programs can be recalled and stored from to PC s hard drive The LCD will display below when PC software are connected and all of the parameters or settings can only be controlled by DxDrive PC Connecting LSS Advanced Speakers Systems via On Longo 53 89024 Polistena RC ITALY tel 39...

Page 19: ...ating point Sampling Rate 96 kHz Analog Converters High Performance 24 bit Propagation Delay 1 5ms Front Panel Controls Display 4 x 32 Character Backlit LCD Level Meters 5 segment LED Buttons Mute Edit Controls One Touch Menu Controls 4 Ways Menu Controls Dial Encoder Embedded Thumb Wheel Connectors Audio 3 pin XLR RS 485 X 2 USB Type B Power Standard IEC Socket General Power 90 120 or 200 240 VAC...

Page 20: ...lopes 12 to 48dB Oct Limiters Threshold 20 to 20dBu Attack 0 3 to 100ms Release 2 to 32X the attack time System Parameters No of Programs 30 10 factory programs and 20 user define Program Names 15 character length Delay Units ms ft m Frequency Modes 36 steps Oct 1Hz resolution Security Lock Lock Unlock Copy channels All parameters with PC software Channel Names 6 character length Note Specificatio...

Reviews: