background image

1

Triac/ELV

Push DIM

Triac/ELV
Push DIM

LM-36-24-G1T2
LM-36-12-G1T2

www.ltech-led.com

Technical Specs

LM-36-12-G1T2

LM-36-24-G1T2

50/60Hz

84% 

85% 

12Vdc

 ± 

0

.

5Vdc

24Vdc

 ± 

0

.

5Vdc

3600Hz

ta: -20

 

~

 

50°C

   

tc: 90°C    

    

-40°C

 

~

 

80°C, 10~95%RH

±0.03%/°C(0-50°C)

Max. 3A

Max. 1.5A

12Vdc

24Vdc

200mV

Max

36W

0

~

36W

102%

Leading edge (Triac), Trailing edge (ELV) phase-cut and Push 

DIM

220-240Vac 

0.2A/230Vac

L-N: 2kV 

Max. 0.5mA

PF>0.95/230Vac , at full load

230Vac@THD

10%, at full load

Shut down the output when non-load

 

voltage

26V, 

re-power on to recover after fault condition is removed.

OUTPUT

Model

INPUT

ENVIRONMENT

PROTECTION

SAFETY &
EMC

Ripple & Noise

PWM frequency

Dimming range

Strobe level

Output voltage range

Output voltage

Output current

Output power range

Output power

Overload power limitation

Leakage current

Control surge capability

Inrush current(typ.)

Efficiency (typ.)

Power factor

Input current

Frequency

Input voltage

Dimming interface 

THD

Working temperature

Working humidity

Storage Temperature humidity

Temperature coefficient

Vibration

Withstand voltage

Isolation resistance

Over-heat protection

Over load protection

Short circuit protection

Over voltage protection

Intelligently adjust or turn off the output current if the PCB temperature 

110°C, and recover automatically .

High frequency exemption level.

dimming down to 0.1%

0~100%, 

Cold start 30A

 

at 230Vac

20 ~ 95%RH, non-condensing

10~500Hz, 2G 12min./1cycle, 72 min for X, Y and Z axes respectively .

I/P-O/P: 3750Vac

I/P-O/P: 100M

Ω

/500VDC/25°C/70%RH

Shut down the output when current load

102%, and recover automatically .

Shut down the output when non-load

 

voltage 

13V, 

re-power on to recover after fault condition is removed.

Shut down automatically if short circuit occurs, and recover automatically .

Safety Standards

EMC Emission

EN61347-1

EN61347-2-13

EN62493

GB19510.1

GB19510.14

EN61347-1

EN61347-2-13

EN62384

KC61347-1

KC61347-2-13

AS61347-1

AS

61347-2-13

EN61347-1

EN61347-2-13

EN62384

IEC61347-1

IEC61347-2-13

IEC61347-1

IEC61347-2-13

GB/T17743

GB17625

.

1

CCC

TUV

CE

KC

RCM

ENEC

CB

EAC

EN55015

EN61000-3-2

EN61000-3-3

EN61547

KN15

KN61547

EN55015

EN61000-3-2

EN61000-3-3

EN61547

CCC

CE

KC

RCM

China

Germany

European Union

Korea

Australia

CB member states

Europe

Russia

China

European Union

Korea

Australia

IEEE 1789

210×43×30mm(L×W×H)

213×44×33mm(L×W×H)

210g±10g

EN61000-4-2,3,4,5,6,8,11,  EN61547

OTHERS

Dimension

Package Size

Weight(G.W.)

EMC immunity

Strobe test standard

IEC62493

IEC61547

EH55015

EAC

Russia

The certification icons represent on-going certification applications only, and final certification qualification is subject to actual products. 

)

短路保护

短路保护

短路保护

Short circuit

protection

Overload

protection

过温保护

过温保护

过温保护

Overheat

protection

V

Over

 

voltage

 

protection

Achieve high frequency exemption level.

Flicker-free

IEEE 1789

Small size and light weight. Adopt SAMSUNG/COVESTRO V0 flame 

resistant polycarbonate protective housings.              

The design of dismountable end cap allows you to adjust the length 

of housing depending on your needs.   

With soft-on and fade in function, visual more comfortable.

Dimming range: 0~100%, dimming down to 0.1%.

0-100% flicker-free, High frequency exemption level.

Leading edge (Triac), Trailing edge (ELV) phase-cut and Push 

DIM.

The secure and reliable design for signal isolation. 

Innovative thermal management technology intelligently protects the 

lifetime the driver. 

Over load / Over temp. / Short circuit / Over voltage protection, 

recover automatically.

Suitable for internal lights application for 

/

/

.

Up to 50000-hour life time.

5 year warranty (Rubycon capacitor).

The driver is suitable for connecting resistor current-limiting LED fixture (e.g. LED strip). The inrush current will be dozens of times increased if connecting built-in constant  current IC current-limiting LED fixtures, the driver will activate the overloaded 
protection (hiccups flickering). When you order, please remark controlling the constant current LED fixture (e.g. MR16 lamp, underground light, LED wall washer, constant current LED strip, etc.), then we can prepare the special programs. 

LED

(Constant Voltage)

  

Intelligent

 

Driver 

440×218×235mm(L×W×H)  60pcs/ctn 13.4kg±5%/ctn

Carton Size

Summary of Contents for LM-36-24-G1T2

Page 1: ... IEC61347 2 13 GB T17743 GB17625 1 CCC TUV CE KC RCM ENEC CB EAC EN55015 EN61000 3 2 EN61000 3 3 EN61547 KN15 KN61547 EN55015 EN61000 3 2 EN61000 3 3 EN61547 CCC CE KC RCM China Germany European Union Korea Australia CB member states Europe Russia China European Union Korea Australia IEEE 1789 210 43 30mm L W H 213 44 33mm L W H 210g 10g EN61000 4 2 3 4 5 6 8 11 EN61547 OTHERS Dimension Package Si...

Page 2: ...htness value when short press on PUSH DIM button Power on again after power cut the output brightness is subjected to the input voltage of drivers Wire diameter 0 5 1 5 20 16AWG Strip length 8mm 9mm Wire diameter 0 75 1 5 20 16AWG Strip length 8mm 9mm Push DIM is invalid for DC voltage input Dimming interface priority Triac first Push DIM next 210 43 30 170 35 157 Tension plate Remove the protecti...

Page 3: ...60 70 80 90 100 0 8 10 12 14 16 50 60 70 80 90 100 AC230V 50Hz 0 2 4 6 8 10 12 14 3 3 15 3 3 3 45 3 6 0 4 8 12 16 20 24 1 5 1 575 1 65 1 725 1 8 AC230V 50Hz Triac ELV Push DIM LM 36 24 G1T2 LM 36 12 G1T2 www ltech led com Relationship Diagrams IO A Efficiency vs Load Efficiency Power Factor Characteristic Load THD vs Load Over Load Diagram Load Load IO A Efficiency vs Load Efficiency Power Factor ...

Page 4: ...dy for customers LTECH is not liable for any incidental or consequential damage unless it is within the law 2 LTECH has the right to amend or adjust the terms of this warranty and release in written form shall prevail Before you power on products please make sure all the wiring is correct in case of incorrect connection that causes damage to light fixtures If a fault occurs please do not attempt t...