background image

Triac/ELV

Push DIM

LM-36-24-G1T2
LM-36-12-G1T2

4

Warranty Agreement

Attentions

Products shall be installed by qualified professionals.

LTECH products are non-waterproof (special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure it is mounted 
in a water proof enclosure.

Good heat dissipation will extend the working life of products. Please ensure good ventilation.

Please check if the working voltage used complies with the parameter requirements of products.

The diameter of wire used must be able to load the light fixtures you connect and ensure the firm wiring. 

This manual is subject to changes without further notice. Product functions depend on the goods. Please feel free to contact our 
official distributors if you have any question.  

Warranty exclusions below:

No any contract signed by LTECH. 

Warranty labels and barcodes have been damaged.

Damage caused by natural disasters and force majeure.

Products with severe physical damage.

Beyond warranty periods.

Warranty periods from the date of delivery : 5

 

years.

Free repair or replacement services for quality problems are provided within warranty periods. 

Any artificial damage caused by high voltage, overload, or improper operations.

1.

 

Repair or replacement provided is the only remedy for customers. LTECH is not liable for any incidental or consequential damage 

    unless it is within the law.

2.

 

LTECH has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.

  

Before you power on products, please make sure all the wiring is correct in case of incorrect connection that causes damage to light fixtures.

If a fault occurs, please do not attempt to fix products by yourself. If you have any question, please contact your suppliers.

Brightness 

0 .1 %

 

1%

5%

30%
40%

70%

90%

100%

10%

20%

50%
60%

80%

Frequency(Hz)

Modulation(%)

1.00%

10.00%

100.00%

0.10%

1

10

100

1000

10000

3125

Flicker Test Table  

IEEE 1789

f

f

≤ 8Hz

≤ 10Hz

Limit value

 (%)

Exemption assessment

(High frequency exemption)

f

f

f

f

f

f

f

f

f

f

≤ 90Hz

≤ 90Hz

≤ 1250Hz

≤ 3125Hz

8Hz <

10Hz <

90Hz <

90Hz <

> 1250Hz

> 3125Hz

0.2

0.1

0.025 

× 

    

0.01 

× 

    

0.08 

× 

    

(0.08

/

2

.

5) 

× 

    

Limit Value of Modulation in Low Risk Areas

 Waveform frequency of Optical output

Exemption assessment

Limit Value of Modulation in No Effect Areas

 Waveform frequency of Optical output

Limit value

 (%)

Modulation Area

High Frequency Exemption Area

Marks in the right chart are tested results of different current levels.

The output frequency is 0Hz in 100% brightness and its corresponding
modulation is 0%, which could not be shown in the right chart.

Update Log

Version

Update

 

Content 

Updated Time

A0

Original version.

2021.04.12

Updated by

Xu

 

Shujun

A1

Updated the silkscreen on the product

.

2021.12.27

Xu

 

Shujun

Update Time: 27/12/2021_A1

www.ltech-led.com

Summary of Contents for LM-36-24-G1T2

Page 1: ... IEC61347 2 13 GB T17743 GB17625 1 CCC TUV CE KC RCM ENEC CB EAC EN55015 EN61000 3 2 EN61000 3 3 EN61547 KN15 KN61547 EN55015 EN61000 3 2 EN61000 3 3 EN61547 CCC CE KC RCM China Germany European Union Korea Australia CB member states Europe Russia China European Union Korea Australia IEEE 1789 210 43 30mm L W H 213 44 33mm L W H 210g 10g EN61000 4 2 3 4 5 6 8 11 EN61547 OTHERS Dimension Package Si...

Page 2: ...htness value when short press on PUSH DIM button Power on again after power cut the output brightness is subjected to the input voltage of drivers Wire diameter 0 5 1 5 20 16AWG Strip length 8mm 9mm Wire diameter 0 75 1 5 20 16AWG Strip length 8mm 9mm Push DIM is invalid for DC voltage input Dimming interface priority Triac first Push DIM next 210 43 30 170 35 157 Tension plate Remove the protecti...

Page 3: ...60 70 80 90 100 0 8 10 12 14 16 50 60 70 80 90 100 AC230V 50Hz 0 2 4 6 8 10 12 14 3 3 15 3 3 3 45 3 6 0 4 8 12 16 20 24 1 5 1 575 1 65 1 725 1 8 AC230V 50Hz Triac ELV Push DIM LM 36 24 G1T2 LM 36 12 G1T2 www ltech led com Relationship Diagrams IO A Efficiency vs Load Efficiency Power Factor Characteristic Load THD vs Load Over Load Diagram Load Load IO A Efficiency vs Load Efficiency Power Factor ...

Page 4: ...dy for customers LTECH is not liable for any incidental or consequential damage unless it is within the law 2 LTECH has the right to amend or adjust the terms of this warranty and release in written form shall prevail Before you power on products please make sure all the wiring is correct in case of incorrect connection that causes damage to light fixtures If a fault occurs please do not attempt t...

Reviews: