Airfusion Climate III Installation Instructions
9
|
P a g e
V1.1-EU (10/ 2019)
PREPARE AND COMPLETE THE ELECTRICAL WIRING --- WIRING DIAGRAM (FIG. 8)
WARNING:
FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A
LICENSED ELECTRICIAN.
NOTE:
AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED
WIRING.
NOTE:
IF THERE ARE TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE LOCATION, AN
ISOLATION SWITCH IS REQUIRED FOR EACH CEILING FAN. THIS IS REQUIRED WHEN
PROGRAMMING THE REMOTE AND RECEIVER TO PAIR TOGETHER.
Ensure the motor earth wire is connected to the sing
le earthing terminal block “1” in the diagram below.
(Fig. 8)
1. Connect the live supply wire
to the “L” terminal of the terminal block on the mounting bracket.
2. Connect the
neutral supply wire to “N” terminal of the terminal block on the mounting bracket.
3. Connect earth wire to the earth terminal of the terminal block on the mounting bracket.
4.
Hang the complete fan assembly onto mounting bracket. (“Hanging the fan” section & Fig. 9)
5. Connect the supply wiring from the mounting bracket to the input of the DC motor driver/receiver.
6. Connect the output wires of DC motor driver/receiver to the input wires of the fan motor and the light kit.
Fig. 8