background image

Moonah Installation Instructions 

 

 

 

2 | 

P a g e  

 

       

 

 

 

THANK YOU FOR PURCHASING 

Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and 

follow all instructions carefully before assembly, installation and use of this ceiling fan. Please keep 

instructions for future reference. 

 

SAFETY PRECAUTIONS 

1.  In  Europe:  This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and  persons  with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been 

given supervision or instruction concerning the use of the appliance in a safe way and understand the 

hazards involved. Cleaning and maintenance shall not be undertaken by children without supervision. 

2.  In Australia: The appliance is not intended for use by persons (including children) with reduced physical, 

sensory  or  mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given 

supervision or instruction concerning the use of the appliance by a person responsible for their safety.   

3.  Children should be supervised to ensure that they do not play with the appliance. 

4.  An  all-pole  disconnection  switch  must  be  incorporated  into  the  fixed  wiring,  in  accordance  with  local 

wiring rules. 

 

IN AUSTRALIA 

WARNING: 

FOR  SAFE  USE  OF  THIS  FAN  AN  ALL-POLE  DISCONNECTION 

MUST  BE  INCORPORATED  INTO  THE  FIXED  WIRING  IN 

ACCORDANCE WITH THE WIRING RULES. 

As outline in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum 

electrical safety of this standard.   

Please note warranty will be void if installation is without a means for an 

all-pole disconnection incorporated in the fixed wiring in accordance with 

the wiring rules. 

Summary of Contents for AIRFUSION MOONAH Series

Page 1: ...V2 0 EN WS 08 2019 AIRFUSION MOONAH SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION ...

Page 2: ...n 2 In Australia The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety 3 Children should be supervised to ensure that they do not play with the appliance 4 An all po...

Page 3: ...esco and coastal areas where the fan is fully undercover with a minimum of 1 wall This fan is not waterproof When installed in an alfresco or coastal area the ceiling fan must be positioned in a location protected from water wind and dust Exposure to these elements will void the warranty Mounting the fan in a situation where it is subject to water or moisture is dangerous and may increase the risk...

Page 4: ...aged in any way Return the complete product to the place of purchase for inspection repair or replacement Examine all parts you should have the following FAN WITHOUT LIGHT FAN WITH LED LIGHT 1 Mounting bracket x 1 1 Mounting bracket x 1 2 Fan assembly with motor down rod canopy and bottom cover x 1 2 Fan assembly with motor down rod canopy and bottom cover x 1 3 Blade x 4 3 Blade x 4 4 Wall switch...

Page 5: ...f carrying a load of at least 30kg with two long screws provided Ensure at least 30mm of the screw is threaded into the support Fig 2 NOTE The bracket screws provided are for use with wooden structures only For structures other than wood the appropriate screw type MUST be used Ensure the screws used are suitable for the mounting surface and the surrounding environment ANGLED CEILING INSTALLATION T...

Page 6: ...unts and blade screws 2 Remove the 2 blade screws and insert the blade into the slot of rotating member of fan motor assembly 3 Align the 2 holes on the blade with the 2 holes on the rotating member of fan motor assembly and using the 2 blade screws in step 2 to secure the blade to the fan motor assembly Ensure all screws are tightened evenly to reduce the chance of warping or unbalancing Take car...

Page 7: ...N ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING NOTE Wiring diagram includes the light kit wiring The light wiring diagram and switch is omitted when no light kit is used with the ceiling fan USE WITH WALL SWITCH WIRING DIAGRAM Ensure the motor earth wire is connected to the single earthing terminal block 2 in the diagram below Fig 6 Fig 6 ...

Page 8: ...EMOTE WIRING DIAGRAM REMOTE sold seperately Ensure the motor earth wire is connected to the single earthing terminal block 2 in the diagram Fig 6 for Fig 7 and Fig 8 1 Remote without plugs 2 Remote with quick connectors using quick connectors Fig 8 Fig 7 ...

Page 9: ...ical wiring is tucked inside the canopy and that the wires are not damaged during this step Secure the canopy to the hanger bracket using the screws provided Fig 9 Switch ON mains power supply to the fan Test the fan operations or enjoy using the fan following instructions the under USING YOUR CEILING FAN section of this instruction manual How to replace the LED driver For models with light kit NO...

Page 10: ...ggle Switch On off REVERSE FUNCTION Your ceiling fan can operate in either summer or winter mode SUMMER Mode The reverse switch should be in the SUMMER position to rotate the fan in an anticlockwise direction The airflow will be directed downwards for cooling in summer WINTER Mode The reverse switch should be in the WINTER position to rotate the fan in a clockwise direction The airflow will be dir...

Page 11: ... a new fan disappear during this time The manufacturer s warranty covers actual faults that may develop and NOT minor complaints such as hearing the motor run All electric motors are audible to some extent CARE CLEANING NOTE Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan Every 6 months periodic cleaning of your ceiling fan is the onl...

Page 12: ...s 48 fan with light DK66 48 L 48 fan only DK66 48 52 fan with light DK66 52 L 52 fan only DK66 52 Rated Voltage 220 240V 50Hz Rated Wattage Motor 75W Rated wattage Lamp 18W 1300lm 3000K N A 18W 1300lm 3000K N A Weight 6 4kg 5 9kg 6 6kg 6 0kg Canopy Dimensions H 54mm Dia 155mm ...

Page 13: ... result of normal wear and tear 3 The product was installed by a licensed electrical contractor 4 A copy of the original receipt of purchase is presented 5 12 month warranty applies when used in any non domestic applications 6 This warranty does not cover stains scratch and scuff marks or dents if the product is purchased through a factory outlet or to refurbished items Our goods come with guarant...

Page 14: ...our personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DATE OF PURCHASE INSTALLING LICENSED ELECTRICIAN LICENCE No ATTACH PROOF OF PURCHASE HERE THIS COMPLETED DETAIL PAGE SHOULD BE PRODUCED AND FAXED TO THE WHOLESALER OR THEIR AUTHORISED AGENTS BEFORE OBTAINING WARRANTY SERVICE ...