background image

Shoalhaven Fan Installation Instructions 

 

 

 

9  | 

P a g e

 

 

REVERSING SWITCH

 

Your ceiling fan can operate in either summer or winter mode.   

 

SUMMER  Mode:

  The  reverse  switch  shall  be  in  the 

SUMMER

  position  to  make  the  fan  rotate  in  an 

anticlockwise direction. The airflow will be directed downwards, for cooling in summer. 
 

WINTER Mode:

 The reverse switch shall be in the 

WINTER

 position to make the fan rotate in a clockwise 

direction. The airflow will be directed upwards assisting in the circulation of warm air, for energy conservation 
in winter. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AFTER INSTALLATION

 

 

WOBBLE: 

NOTE: Ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet. 

If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres 

is quite acceptable and DOES NOT suggest any problem.  

TO REDUCE THE FAN WOBBLE:

 Please check that all screws which fix the mounting bracket and down rod 

are secure.  

BALANCING KIT: 

A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to 

the instruction on how to use the balancing kit.

 

The balancing kit can be used to assist re-balancing should 

the  ceiling  fan  become un-balanced  again.  Store  your  balancing  kit  away  after  installation for  future  use  if 

required.

 

 

 

NOISE: 

When  it  is  quiet  (especially  at  night)  you  may  hear  occasional  small  noises.  Slight  power  fluctuations  and 

frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan 

motor noise. This is normal. Please allow a 24-

hour “breaking-in” period, most noises associated with a new 

fan disappear during this time. Please note that this is not a product fault and as such is not covered under 

warranty 

– All electric motors are audible to some extent. 

 

Fig. 14 

Summary of Contents for AIRFUSION SHOALHAVEN

Page 1: ...V1 0 EN WS 08 2018 LUCCI AIRFUSION SHOALHAVEN CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION ...

Page 2: ... sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety 3 Children should be supervised to ensure that they do not play with the appliance 4 An all pole disconnection switch must be incorporated into the fixed wiring in accordance with local wiring rules I...

Page 3: ... 3 m above the floor in Europe or 2 1 m above the floor in Australia 8 This fan is designed for indoor use only Mounting the fan in a location where it is subject to water or moisture is dangerous and may increase the risk of damage injury or electrical shock and will void the warranty 9 Must be assembled and installed by a licensed electrician 10 WARNING If unusual wobbling or oscillating movemen...

Page 4: ...ny way Return the complete product to the place of purchase for inspection repair or replacement Examine all parts you should have the following FAN WITHOUT LIGHT FAN WITH LED LIGHT 1 Mounting bracket x 1 1 Mounting bracket x 1 2 Pre assembled fan motor down rod and canopy x 1 2 Pre assembled fan motor down rod and canopy x 1 3 Bottom cover x 1 3 Light bracket x 1 4 Blade x 3 4 Globe x 1 5 Blade b...

Page 5: ...ed into the support Fig 2 NOTE The bracket screws provided are for use with wooden structures only For structures other than wood the appropriate screw type MUST be used Ensure the screws used are suitable for the mounting surface and the surrounding environment ANGLED CEILING INSTALLATION This fan hanging system supports a maximum 15 degree angled ceiling installation Fig 3 HANGING THE FAN Lift t...

Page 6: ... warping or unbalancing Take care not to over tighten the screws as this can damage the blades Repeat the process for the remaining blades INSTALLING THE BOTTOM COVER FOR FAN WITHOUT LIGHT Install the bottom cover onto the motor shaft by rotating it clockwise Fig 6 INSTALLING THE LIGHT KIT FOR FAN WITH LIGHT Join the connectors 2 together and place into the connection box 1 Fig 7 Install the light...

Page 7: ...TE AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING NOTE Wiring diagram includes the light kit wiring The light wiring diagram and switch is omitted when no light kit is used with the ceiling fan USE WITH WALL SWITCH WIRING DIAGRAM Ensure the motor earth wire is connected to the single earthing terminal block 2 in the diagram below Fig 9 Fig 9 ...

Page 8: ...NG DIAGRAM REMOTE sold separately Ensure the motor earth wire is connected to the single earthing terminal block 2 in the diagram Fig 9 for Fig 10 and Fig 11 1 Remote without quick connectors manual wiring 2 Remote with quick connectors using quick connectors Fig 10 Fig 11 ...

Page 9: ...g 12 Switch ON mains power supply to the fan Test the fan operations or enjoy using the fan following instructions the under USING YOUR CEILING FAN section of this instruction manual USING YOUR CEILING FAN FAN WALL CONTROL Turn on the power and check the operation of the fan OFF Position Fan off 3rd Position Low fan speed 2nd Position Medium fan speed 1st Position High fan speed LIGHT CONTROL Togg...

Page 10: ...e acceptable and DOES NOT suggest any problem TO REDUCE THE FAN WOBBLE Please check that all screws which fix the mounting bracket and down rod are secure BALANCING KIT A balancing kit is provided to balance the ceiling fan on initial installation Please refer to the instruction on how to use the balancing kit The balancing kit can be used to assist re balancing should the ceiling fan become un ba...

Page 11: ... your ceiling fan in the water or other liquids It could damage the motor or the blades and create the possibility of an electrical shock Ensure that the fan does not come in contact with any organic solvents or cleaners To clean the fan blade wipe with only a damp clean cloth with NO organic solvents or cleaners The motor has a permanently lubricated ball bearing so there is no need to oil TECHNI...

Page 12: ...as a result of normal wear and tear 3 The product was installed by a licensed electrical contractor 4 A copy of the original receipt of purchase is presented 5 12 month warranty applies when used in any non domestic applications 6 This warranty does not cover stains scratch and scuff marks or dents if the product is purchased through a factory outlet or to refurbished items Our goods come with gua...

Page 13: ...or your personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DATE OF PURCHASE INSTALLING LICENSED ELECTRICIAN LICENCE No ATTACH PROOF OF PURCHASE HERE THIS COMPLETED DETAIL PAGE SHOULD BE PRODUCED AND FAXED TO THE WHOLESALER OR THEIR AUTHORISED AGENTS BEFORE OBTAINING WARRANTY SERVICE ...