Nordic Installation Instructions
10 |
P a g e
THE RECEIVER PROVIDES THE FOLLOWING LEVEL OF PROTECTION:
Lock position: the receiver has a built in safety feature to protect against obstruction during operation. The motor
will be locked from operation and will disconnect from power after 30 seconds of interruption. Please remove
obstacles before re-starting. To reset, simply turn off the power supply to the fan motor and re-start.
Over 80W protection: when the receiver detects power consumption which is greater than 80W, the receiver power
will be stopped and operation will immediately discontinue. Turn the receiver power on after 5 seconds to restart the
fan.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the
receiver must be repaired. Below are the operating symptoms and method to repair the pairing of the DC ceiling
fan remote and receiver.
Issues:
Loss of control - Fan is only running at high speed after installation
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with receiver
Solution:
A. Switch OFF the main power to ceiling fan for 30 seconds.
B.
Press and hold the “
” button on
transmitter
for 3
-
5 seconds within 60 seconds of switching the power ON to
the receiver of the ceiling fan.
C. Turn ON and change the speed of the ceiling fan via the transmitter to check the operation and successful paring.
AFTER INSTALLATION
WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet. If the fan
was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres is quite acceptable
and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE:
Please check that all screws which fix the mounting bracket and down rod are secure.
BALANCING KIT:
A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction
on how to use the balancing kit.
The balancing kit can be used to assist re-balancing should the ceiling fan become un-
balanced again. Store your balancing kit away after installation for future use if required.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and
frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan
motor noise. This is normal. Please allow a 24-
hour “breaking-in” period, most noises associated with a new
fan disappear during this time. All electric motors are audible to some extent. Please note that this is not a
product fault, and as such is not coverd under warranty.