Remote Port Security Device
User’s Guide
555-024-402
Issue 1
October 1996
Installation
Page 2-8
Installation
2
Figure 2-2.
RPSD Lock to Central Office Line (RMATS Channel)
To connect the RPSD Lock to the central office line, follow these steps:
1. The customer must contact the Technical Support Center to get the port
number for the RMATS channel.
2. Locate the central office line for the RMATS port and install an RJ11
receptacle on the central office line.
3. Connect one end of the 14-foot telephone line cord with RJ11 connectors
to the central office line.
4. Plug the RJ11 connector on the other end of the telephone line cord into
the TELCO port on the back of the RPSD Lock.
SUBSCRIBER
(MODEM)
TELCO
AUX. PORT
+
!
12VDC
1A
ALARM
LEADS
POWER MONITOR
RED
GREEN
BYPASS
SECURE
RPSD Lock
RJ11
Connector
RJ II
Jack
Tip and Ring Wires
CO Line
(RMATS Channel)
RJ11
Connector