Response:
8.22 View is populated.
6.
Verify value of field 4
ACTIVE
7.
If
ACTIVE
is
YES
, continue with next Step.
If
ACTIVE
is
NO
, notify Lucent Regional Engineer to turn on SFID in order to activate the feature. This
procedure cannot be continued until SFID is activated. Exit RC/V menu and return to Procedure start.
8.
At the MCC of STLWS, to backup ODD, type and enter
bkup:odd,am;
Response:
BKUP ODD AM COMPLETED
BKUP ODD COMPLETED
(Backup will require several minutes to complete.)
NOTE: bkup:odd, am;
is required to acknowledge that the SFID is on.
9.
Exit RC/V menu.
14.1.2 Perform Preliminary Requirements
1.
At the MCC (Maintenance Control Center), to inhibit automatic maintenance requests, enter
INH:DMQ:SRC=ALL;
Response:
The system displays
OK
NOTE:
At the ROP, the following response will periodically appear:
REPT DMQ INHIBIT ALL ACTIVE
NOTE:
For this procedure, the ECD should be accessed by command mode only.
14.1.3 Test MTTYCs From Both CUs
1.
Set both switches on port switch circuit pack UN377 (at EQL 045-186) to
AUTO
position.
2.
At the MCC, to display AM, AM PERIPHERALS Page, enter Poke command
111/112
Response:
AM, AM PERIPHERALS Page is displayed.
3.
At the MCC, verify that CU 0 is active.
If
YES
, go to Step 5.
If
NO
, continue with next Step.
4.
At the MCC, to switch to CU 0, enter
SW:CU;
Response:
The system displays
SW CU 0 COMPLETED
5.
At the 111/112 Page, verify that the MTTY is connected to MTTYC 1.
235-105-210
October 1999
Copyright © 1999
Page 2
Summary of Contents for 5ESS-2000
Page 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Page 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Page 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Page 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Page 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Page 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Page 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Page 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...