Procedure 15.67: INITIALIZE THE AMA SYSTEM PROCESS (AMDC) IN EACH SM
PROCEDURE
1.
CAUTION:
This message will purge the requested process. Any activity currently in progress
will be killed. This may result in other asserts or audits as the system cleans up.
2.
Verify the switching modules (SM) in your office.
At master control center (MCC), type and enter
OP:SYSSTAT,UCL;
Response:
If
NG
- No good. The message was not accepted because an illegal SM or CMP number or
invalid range/type combinations was specified.
If
PF
- Printout follows. The message was accepted and the
OP:SYSSTAT-SUM
output
message follows which specifies the current off-normal conditions for the specified modules.
NOTE:
The SMs from the output message not in growth will be used in the following step. If the SM is in
standalone, the following procedure will need to be completed upon the SM returning from
stand-alone operation.
3.
For each SM in your office, initialize its AMA system process, AMDC.
At master control center (MCC), type and enter
INIT:SM=x,SPP,PID=34;
Where:
x = SM number whose AMA process you wish to initialize.
Response:
If
NG
- No good. The message was not accepted for one of the following reasons:
- An illegal SM number was specified.
- An illegal initialization level or process identification (PID) was specified.
If
IP
- In progress. The message was accepted, and the request is in progress. Wait for an
INIT SM=x LVL=SPP COMPLETED
response message before continuing.
Where:
x = SM number whose AMA process was initialized.
4.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
235-105-210
October 1999
Copyright © 1999
Page 1
Summary of Contents for 5ESS-2000
Page 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Page 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Page 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Page 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Page 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Page 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Page 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Page 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...