Reference:
Procedure 11.1
2.
At the RC/V terminal, type and enter
19.14R
Response:
DIGITAL NETWORKING UNIT SONET (SM-2000)
page displayed.
3.
Type and enter appropriate data for each attribute listed in the following display.
1. SM ___
2. DNUS _
Response:
System completes remainder of view.
Enter Review, Change-insert, Validate, or Print:
4.
Verify that the PCT link corresponding to the selected DS1(s) is operational for both common data (CD)s.
The PCT link number and the STS-1 number are the same. For example, if the STS-1 number is 2 in data
group 1, the PCT link number will be 2 for both CDs.
Comment:
If not operational, refer to the DNU-S PCT LINK GROWTH PROCEDURE in 235-105-231,
5ESS
®
-2000 Switch Hardware Change Procedures
Growth
and correct using terminal in
the update mode.
5.
Type and enter
<
Response:
19.0 SM UNIT VIEWS
page displayed.
11.29.8 Verify Sufficient UODD Space in the SM Data Base
1.
A full 28 VT1.5 and 28 DS1 facilities grown in on a single STS-1 facility will require at least 1350 Kbytes of
UODD space. Verify that sufficient space is available.
Reference:
Procedure 6.25
- SM ODD Memory Growth
11.29.9 Allow Automatic Data Base Relation Reorganization
1.
At MCC, type and enter
ALW:REORG;
Response:
OK
11.29.10 Insert VT1.5/DS1 Facility Data Into Data Base
1.
Type and enter
20.24i
Response:
DIGITAL NETWORKING UNIT SONET VIRTUAL TRIBUTARY (SM-2000)
page displayed.
Cursor at SM attribute.
2.
Usin the selected work order form as a guide, type and enter the indicated values for each KEY attribute.
1. SM ___
2. DNUS _
235-105-210
October 1999
Copyright © 1999
Page 4
Summary of Contents for 5ESS-2000
Page 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Page 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Page 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Page 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Page 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Page 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Page 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Page 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...