11.41.6 CONDITIONALLY RESTORE PSU COMMON SIDE 1
1.
At the MCC, type and enter
RST:PSUCOM=a-b-1
Where:
a = SM number
b = PSU number = 0
Response:
RST PSUCOM=a-b-1 COMPLETED
NOTE:
A COMPLETED response must be achieved in this Step before continuing.
11.41.7 DIAGNOSE PSU COMMON SIDE 0
1.
At the MCC, type and enter
DGN:PSUCOM=a-b-0
Where:
a = SM number
b = PSU number = 0
Response:
DGN PSUCOM=a-b-0 COMPLETED ATP
NOTE:
A COMPLETED ATP must be achieved in this Step before continuing.
11.41.8 UPDATE DATA FANOUT CHANGE LEVEL INDICATOR VALUE FOR SIDE 0
1.
Select and prepare terminal for recent change and verify (RC/V) activities.
Reference:
Procedure 11.1
2.
What shelf is conversion taking place?
If,
PSU Shelf 0
, continue with next Step.
If,
PSU Shelf 1-4
, then go to Step 12
3.
At the RC/V terminal, type and enter
22.2U
Response:
EQUIPMENT UNIT -- PACKET SWITCH UNIT
page displayed.
Cursor at SM attribute.
4.
Select the completed growth recent change and verify (GRCV) form
22.2
for the identified PSU. This form
should have the KEY attributes listed in the following display:
*1.
SM
____
*2.
PSU
____
5.
Using the selected GRCV form as a guide, type and enter the value for each KEY (*) attribute listed.
Response:
System completes remainder of form.
Enter Update, Change, Validate, screen#, or Print:
6.
Type and enter
C
Response:
Change field:
235-105-210
October 1999
Copyright © 1999
Page 6
Summary of Contents for 5ESS-2000
Page 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Page 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Page 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Page 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Page 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Page 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Page 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Page 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...