D-4
APX 1000™ Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Environmental specifications
Environmental specifications
For best results, install the APX 1000 unit in an environment with constant temperature and
humidity. In general, cooler environments are better. Humidity must be high enough to prevent
accumulation of static electricity, but low enough to prevent condensation.
Table D-4 describes the environmental requirements for selecting an installation site for the
APX 1000 hardware. The site requirements are based on Network Equipment Building System
(NEBS) GR-63-CORE.
Unit weight
40 pounds (18.2kg) maximum (fully configured)
Table D-3. APX 1000 physical specifications (continued)
Specification
Description
Table D-4. APX 1000 site specifications
Parameter
Requirement
Ambient operating temperature
0°C to 50°C (32°F to 122°F)
Ambient storage temperature
-40°C to +65.56°C (-40°F to +150°F)
Relative humidity
5% to 95% non condensing at 50°C (122°F)
Operating altitude
13,000 feet (3962m) at 77°F (25°C)
Storage altitude
18,730 feet (5709m) at 77°F (25°C)
Vibration
5Hz to 500Hz with 2.4G rms peak