IOP and IOA Module Specifications
32-port Channelized T1/E1 FR/IP IOM
Beta Draft Confidential
CBX 500 Multiservice WAN Switch Hardware Installation Guide
4/5/03
A-7
Interface Standards
•
American National Standards Institute (ANSI) T1.231 (performance monitoring)
Other Standards
•
Frame Relay Forum FRF.5, FRF.8, and FRF.16
•
ITU-T G.703
•
ITU-T G.704 — basic frame structure and cyclic redundancy check (CRC)
implementations
•
ITU-T G.826 (performance parameters)
•
E1 Management Information Base (MIB) — Request For Comment (RFC) 1406
(for near-end statistics)
•
RFC 1490 translation FRAD
•
HDLC/SDLC encapsulation FRAD (for X.25 traffic)
•
CE Mark
Physical Interfaces
32 physical ports per IOA module:
•
T1 mode: 24 DS0 channels per physical port (768 logical ports per IOM, each at
64 Kbps)
•
E1 mode: 30 TS0 channels per physical port (960 logical ports per IOM, each at
64 Kbps)
Physical Connectors
•
32-Port Channelized T1 FR/IP I/O connector panel: RJ48, 100-ohm
•
32-Port Channelized E1 FR/IP I/O connector panel: RJ48, 120-ohm