Table 3-2
ED8C900-20 DS3 Cable Assemblies
Application
(Note 1)
Length Per
Table 2-2
*
Column
Factory
Term.
Groups
†
Cable Type
(Note 2)
Connectors
Types
Cables
Per
Muldm
Cables
per
Shelf
DSX-3 or FT-2000
1A
AB, LA
735A
Straight
BNC to
Right Angle
BNC
6
24
OC-48
2A
6BB, 6LA
1735006A
1
6
4A
DBD, 1LA
735A-734D
6
24
4A
DB, 1LA
734D
6
24
DACS III-2000
With BNC
Interconnect Shelf
1A
AB, LA
735A
Straight
BNC to
Right Angle
BNC
6
24
2A
6BB, 6LA
1735006A
1
6
4A
DBD, 1LA
735A-734D
6
24
4A
DB, 1LB
734D
9821AE to
Right Angle
BNC
6
24
Without BNC
Interconnect Shelf
1A
AC, LB
735A
6
24
2A
6BC, 6LB
1735006A
1
6
4A
DBD, LCD
735A-734D-
735A
6
24
DACS IV-2000
With BNC
Interconnect Shelf
1A
AB, LA
735A
Straight
BNC to
Right Angle
BNC
6
24
2A
6BB, 6LA
1735006A
1
6
4A
DBD, 1LA
735A-734D
6
24
4A
DB, 1LA
734D
6
24
Without BNC
Interconnect Shelf
1A
AE, LB
735A
9821FA/
9821AE to
Right Angle
BNC
3
12
AD, LB
3
12
2A
6BJ, 6LB
1735006A
1
6
4A
DBD, LED
735A-734D-
735A
9821AE to
Right Angle
BNC
3
12
DBD, LDD
3
12
Table 3-2 Notes:
1. All the DS3 cable assemblies can be used for any muldem. The OC-12 DS3 backplane connectors are
J30-J35 (for muldem A), J36-J41 (for muldem B), J42-J47 (for muldem C), and J48-J53 (for muldem D).
* 1A, 2A and 4A refer to Table 2-3 columns on Pages 2-35 and 2-36 providing the cable lenghts and asso-
ciated Cable Group numbers. This information is also shown on ED8C900-20.
† This column lists the ED8C900-20 Groups for factory terminations at each end of the cable.
Summary of Contents for DDM-2000 OC-12