Issue 5 November 2000
363-206-208
Powering, Verification, and Circuit Pack Installation for the DDM-2000 OC-12 Multiplexer
Lucent Technologies - Proprietary
See Notice on first page
SYSCTL Switch 3 Notes:
1. Switch section 8 must be set to OFF.
2. An invalid data rate setting will revert to 1200 baud, generate an alarm, light the SYSCTL FAULT
LED, and set TBOS point 14.
NOTE:
TBOS is not available in OC-12, Release 7.
SYSCTL Switch 4 Notes:
1. The TBOS terminator is the physical termination of the telemetry daisy-chain. Set the TBOS termi-
nator for “last” if the shelf is the last shelf position on the telemetry daisy-chain at the CO, where
the initial link is made.
2. Set the TBOS terminator for “not last” if the shelf is not the last shelf on the telemetry daisy-chain.
3. Set all RT applications as “not last”.
Figure 5-3 (Continued). BBG5 SYSCTL Option Switches (Sheet 4 of 4)
Switch 3 Settings
Front Access Data Rate
Rear Access Data Rate
Power Minor
Value
Sec 1
Sec 2
Sec 3
Value
Sec 4
Sec 5
Sec 6
Value
Sec 7
300
OFF
OFF
OFF
300
OFF
OFF
OFF
Office Minor
OFF
1200
OFF
OFF
ON
1200
OFF
OFF
ON
2400
OFF
ON
OFF
2400
OFF
ON
OFF
4800
OFF
ON
ON
4800
OFF
ON
ON
9600
ON
OFF
OFF
9600
ON
OFF
OFF
Office Major
ON
19200
ON
OFF
ON
19200
ON
OFF
ON
(Invalid)
ON
ON
OFF
(Invalid)
ON
ON
OFF
(Invalid)
ON
ON
ON
(Invalid)
ON
ON
ON
Switch 4 Settings
TBOS Terminator
Shelf Location
Sec 1
Sec 2
Not Last
OFF
OFF
Last
ON
OFF